Home / Products / Steel Truss / Secondary Structural System
Secondary Structural System
Steel Truss Purlins
Purlins are secondary load-bearing members in the roof system that support roof panels. Arranged perpendicular to roof beams, they transfer dead loads, live loads, and wind loads from the roof panels to the roof beams or rigid frame rafters. Common forms include C-section, Z-section, H-beam, and square tube purlins. Among them, C and Z cold-formed thin-walled purlins are most widely used in portal frame lightweight buildings due to their light weight and easy installation. Z-section purlins can be overlapped to form continuous spans, resulting in smaller mid-span bending moments; C-section purlins are simple to manufacture and connect. Sag rods and struts are usually installed between purlins to reduce the out-of-plane effective length of the roof.
Technical Specifications
| Parameter | Specification |
|---|---|
| Common Sections | C-section, Z-section, square tube, H-beam |
| Section Height | C120~C350, Z120~Z350 |
| Wall Thickness Range | mm ~ 3.5mm |
| Material | Q235B/Q355B (Galvanized layer ≥180g/m²) |
| Spacing | m ~ 1.5m (determined by panel type and load) |
| Span | Simply supported 6m~9m, continuous Z-sections can be larger |
| Connection Method | Self-tapping screws to roof panels, bolts to rigid frame rafters |
| Accessories | Sag rod, steel purlin spacer tube, strut, flange brace |
| Anti-corrosion Treatment | Galvanized (default), or painted after strip steel forming |
| Execution Standard | GB 51022, GB/T 6725 |
Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.
Advantages vs Engineering Considerations
| Advantages | Engineering Considerations |
|---|---|
| Light weight, steel saving: Cold-formed thin-walled purlins save 30%~50% steel compared to H-beam purlins. | Corrosion damage on thin-walled members needs attention: Galvanized layer scratches during transport/installation must be touched up, otherwise rust easily occurs. |
| Convenient installation: C/Z purlin lengths can be customized, bolted on-site, ensuring fast construction. | Requires sag rods for torsion: Purlins easily suffer from flexural-torsional buckling down the roof slope; sag rods must be set as designed. |
| Z-sections can continuously overlap: Reduces mid-span bending moments, allowing for smaller purlin cross-sections. | Reverse bending for purlins in wind uplift zones: Roof corners have high wind suction; purlin design must account for reverse bending conditions. |
| Mature accessory system: Sag rods, steel purlin spacer tube, and flange braces are standardized, offering good overall economy. | Self-tapping screw leakage risk: Connections between panels and purlins require waterproof washers and standard drilling. |
| Galvanized anti-corrosion: Anti-corrosion is completed ex-factory, no on-site painting needed, low maintenance cost. | Wall thickness limit: Thickness exceeding 3.5mm usually switches to H-beams or square tubes to meet bearing capacity. |
Frequently Asked Questions
What are the types of purlins?
C-section, Z-section, square tube, H-beam purlins. C/Z types are common for light plants.
How to choose between C and Z purlins?
Z purlins can continuously overlap and save steel; C purlins are simple to make and install, often used for smaller spans.
What is the proper purlin spacing?
Commonly 0.5~1.5m, determined by roof panel stiffness and load calculations.
Why add sag rods to purlins?
To reduce the out-of-plane effective length of purlins and prevent flexural-torsional buckling.
What material is used for purlins?
Q235B/Q355B hot-dip galvanized strip steel, usually with galvanizing amount ≥180g/m².
How are purlins connected to roof panels?
Fixed to purlins by self-tapping screws (with waterproof washers) penetrating the panels, or using dedicated concealed brackets.
What is the function of a flange brace?
Connects purlins to the lower flange of the rigid frame rafter, preventing the lower flange from compressive buckling.
What is the typical purlin span?
C-sections (simply supported) typically 6~8m; Z-sections (continuous overlapping) can reach 9m or more.
Do galvanized purlins need on-site painting?
Generally no; scratched areas during transport/installation require anti-rust touch-up paint.
What to note for purlin design in high-wind areas?
Purlins in edge/corner wind suction zones need reverse bending verification, and connection bolts/sag rods should be densified.
Qualification Certificate
Your projects are protected by world-class standards. From CE (EN 1090) to ISO 9001, our qualifications are not just paper—they are the rigorous daily reality on our shop floor.




Have drawings or a BOQ ready?
Related Projects
Projects where this sub-system was detailed, fabricated and shipped as part of the structural package.
SynJect:Scale. Precision. Certainty.
SYNJECT delivers comprehensive steel structure solutions engineered for the global value chain. From investors seeking ROI to engineers demanding exact compliance, we transform complex blueprints into robust realities—on time and without friction.
From Blueprint to Site. Zero Friction.











Detailed Engineering
Utilizing advanced BIM platforms such as Tekla Structures, detailed 3D modeling and shop drawings are executed strictly in compliance with AISC 360 or Eurocode 3 (EN 1993). Connection designs are rigorously verified, with manufacturing drawings generated to ISO 2768-m tolerance standards. 100% clash detection with primary architectural and MEP systems is performed to ensure zero structural conflicts during field erection.
Nesting & Material Optimization
Intelligent nesting layouts are performed using advanced software like FastCAM/SigmaNEST in accordance with EN 10029 / ASTM A6 dimensional standards. Accounting for cutting kerf (2mm–5mm depending on plate thickness) and thermal contraction allowances, raw material utilization exceeds 92%. Offcuts are digitally barcode-tracked to ensure 100% mill test report (MTR) traceability.
Raw Material Incoming Inspection
All structural steel (Q355B/C/D, ASTM A572 Gr.50, S355JR/J2) must be accompanied by EN 10204 3.1 Mill Test Reports (MTR). Incoming quality control conducts 100% dimensional and visual inspections under ASTM A6 / EN 10029, verifying thickness tolerances (Class A/B) and internal lamination integrity via Ultrasonic Testing (UT) to ASTM A435. Chemical composition and mechanical properties are spot-verified by accredited 3rd-party labs.
CNC Cutting & Edge Preparation
Plate profiling and component cutting are executed via CNC oxy-fuel, high-definition plasma, and multi-kW fiber laser equipment. Cut surface quality strictly complies with EN ISO 9013 for perpendicularity and surface roughness ±2.5°, Range 3/4 tolerance. Multi-axis CNC beveling machines execute weld prep bevel angles within ±2.5° and root face dimensions within ±1.0 mm.
Weld Distortion Straightening
Welding is performed exclusively by AWS D1.1 or EN ISO 9606 certified welders using qualified Welding Procedure Specifications (WPS) supported by Procedure Qualification Records (PQR) per AWS D1.1 / ISO 15614. Submerged Arc Welding (SAW) and Flux-Cored Arc Welding (FCAW) dominate Complete Joint Penetration (CJP) and fillet welds. Heat input is strictly controlled, achieving weld quality levels conforming to ISO 5817 Quality Level B or AWS D1.1 standards.
Non-Destructive Testing (NDT)
Post-weld angular distortion, camber, and sweep are rectified using automated hydraulic flange straighteners and controlled thermal flame straightening. Heating temperatures for High-Strength Low-Alloy (HSLA) steels are strictly maintained between 600℃ - 650℃ (air-cooled, zero water quenching) to prevent microstructural degradation. Post-straightening straightness tolerances meet ±3 mm, conforming to EN 1090-2 Execution Class 2 (EXC2) and AISC COSP standards.
Trial Assembly & Shop Alignment
NDT protocols are operated by ISO 9712 / ASNT Level II certified NDT personnel. 100% of critical Complete Joint Penetration (CJP) welds undergo Ultrasonic Testing (UT per ISO 17640 / ASTM E164) or Magnetic Particle Testing (MT per ISO 17638 / ASTM E709). Radiographic Testing (RT) is applied as requested for heavy sections. Weld acceptance conforms strictly to ISO 11666 Acceptance Level 1 or AWS D1.1 criteria.
Surface Preparation & Protective Coating
Complex geometries, long-span trusses, and heavy framing undergo 1:1 physical trial assembly or high-precision 3D laser scanning virtual assembly per EN 1090-2 / AISC requirements. Bolt hole alignment is verified (≥ 95% free-pass rate for high-strength bolts), and critical dimensions (span, camber, 3D spatial alignment) are verified within tight tolerance limits (±2.0 mm) to eliminate site fitting risks.
Measure Paint Film Thickness
Structural members undergo automated shot blasting to achieve SSPC-SP10 / NACE No. 2 / ISO 8501-1 Sa 2.5 cleanliness, with a surface profile (anchor depth) of 45–75μm. High-performance protective coatings are applied using airless spray technology in compliance with ISO 12944 (C3 to CX corrosive environments), featuring Inorganic/Organic Zinc-Rich Epoxy Primers, Epoxy Micaceous Iron Oxide Intermediate coats, and Polyurethane/Fluorocarbon Topcoats. Dry Film Thickness (DFT) is verified using calibrated magnetic gauges adhering strictly to the 90/10 rule.
Final Quality Inspection & Certification
Final Quality Control (FQC) performs a comprehensive holistic audit, inspecting paint aesthetics (zero runs, pinholes, sagging), critical geometry, bolt hole pitches, and laser/stenciled component mark traceability. A complete Manufacturing Data Report (MDR)—comprising MTRs, NDT records, coating inspection logs, and Certificates of Conformance—is compiled to support CE Marking (DoP under EN 1090) and AISC final acceptance.
Export Packaging & Logistics Protection
Protective packaging is engineered for containerized (40HQ/OT/FR) and breakbulk ocean freight under heavy maritime transit conditions. Structural members are bundled on heavy-duty steel skids with high-tensile steel strapping. Machined connections and contact surfaces are wrapped with VCI anti-corrosion film, EPE foam padding, and heavy rubber cushions. All timber packing complies fully with ISPM 15 phytosanitary standards and IMO Cargo Stowage and Securing (CSS) rules.
Global Field Erection & Site Management
We deliver international site erection supervision and turnkey EPCM construction services adhering to OSHA 1926 safety protocols, AISC COSP, and EN 1090-2 erection standards. Field teams, led by multilingual HSE and QA/QC engineers, utilize high-precision total stations to maintain structural plumbness within H/1000 (≤25mm max). High-Strength Structural Bolting is executed via calibrated Wrench or Turn-of-Nut methods with 100% torque audit documentation.
Get Your 24-Hour BOQ and Cost Plan
See how much steel tonnage and ocean freight you can save before fabrication begins
Steel Weight Savings
1:1 Tekla 3D modeling optimizes beam-column ratios to eliminate redundant material costs.
Zero-Clash Code Verification
Checked against EN 1090 and local wind/seismic loads.
Engineer-to-Engineer Review
Verified by our lead engineers—Zero pushy sales calls, Just actionable data and factory price.
CE EN 1090-1•ISO 9001•ISO 14001•ISO 45001
Lead Engineers Online
🔒 100% Private and Secure, No Spam