Home / Products / Steel Truss / Bracing System

Bracing System

Roof horizontal bracing, sag rod and steel column bracing plus related components forming the bracing system of a steel truss

Steel Column Bracing · Roof Horizontal Bracing · Flange Brace · Sag Rod · Steel Purlin Spacer Tube · Steel Gutters · Eave Strut Purlin

What we fabricate in this sub-system

Cross-braced rod or angle systems in the wall plane supplied for a steel truss

Steel Truss Steel Column Bracing

Steel Column bracing (inter-column bracing) is a bracing system installed between adjacent longitudinal column rows in a plant. It withstands the plant's longitudinal horizontal loads (crane longitudinal braking forces, wind loads, seismic action) and ensures the plant's longitudinal stiffness and overall stability. By layout position, it can be divided into upper column bracing and lower column bracing; by form, into cross (X) bracing, V-bracing (chevron), inverted V-bracing, and portal bracing. Column bracing, together with roof transverse bracing and Eave Strut Purlin, forms a spatial geometric invariable system, acting as a critical component for the plant's longitudinal seismic and wind resistance.

Technical Specifications

Parameter Specification
Common Forms Cross bracing, V-bracing, inverted V-bracing, portal bracing
Section Forms Round steel, angle steel, circular tube, H-beam, rolled channel steel
Material Q235B, Q355B
Installation Position Middle column rows of the plant's temperature section
Function Transfer longitudinal horizontal forces, ensure longitudinal stiffness
Connection Method Welded or bolted via gusset plates to the columns
Material Specifications Commonly ø20, ø25 round steel, L75×5~L140×10 double angle steel built-up sections
Tensioning Device Cross round steel bracing can be equipped with turnbuckles for tensioning
Layered Setup Upper column bracing (above crane beams) and lower column bracing (below crane beams)
Execution Standard GB 50017, GB 51022

Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Improves longitudinal stiffness: Significantly reduces plant longitudinal lateral drift, ensuring overall structural stability. Affects building usage: Cross bracing may interfere with doors and process layouts; coordination with architecture is needed.
Transfers horizontal forces: Effectively transfers crane longitudinal braking forces, wind loads, and seismic action. Heavy gusset plate welding: Cross bracing gussets involve many welds; welding deformation must be controlled.
Flexible layout: Cross, V-shape, and portal forms adapt to various process and doorway requirements. Tensioning degree must be controlled: Round steel cross bracing must be tensioned during installation, otherwise it is ineffective.
Material-saving: Bracings are designed as two-force members, requiring little steel. Temperature section layout: Bracing should be located in the middle of a temperature section to avoid temperature stress concentration.
Factory prefabrication: Members fabricated in the factory, bolted on-site. Seismic nodes must follow codes: Bracing nodes in seismic zones must be designed according to seismic levels.

Frequently Asked Questions

What is the function of steel column bracing?

Ensures longitudinal stiffness of the plant, transfers longitudinal horizontal forces, and prevents lateral drift instability.

Cross bracing, V-bracing, inverted V-bracing, portal bracing.

Above the crane beams is upper bracing; below is lower bracing, bearing horizontal forces at different heights.

Round steel sections (for hinged bases without cranes), double angle sections (with cranes); large spans may use tubes or H-beams.

In the middle and ends of the plant's temperature section column rows to avoid excessive temperature stress.

To prevent slack and ensure immediate action when subjected to tension.

Column bracing + roof transverse bracing + Eave Strut Purlin form a spatial geometric invariable system.

Can switch to portal bracing or inverted V-bracing to bypass doorways.

Welded or high-strength bolted to the column side connection plates via gusset plates.

Bracing diagonal slenderness ratio, gusset plate thickness, and connection welds must be strengthened per seismic levels.

Round bar or angle roof bracing in the roof plane supplied for a steel truss

Steel Truss Roof Horizontal Bracing

Roof Horizontal bracing is a bracing system arranged in the plane of the upper or lower chords of the roof truss (or rigid frame). Together with column bracing and Eave Strut Purlin, it forms the spatial stability system of the plant. By position, it can be divided into upper chord transverse horizontal bracing, lower chord transverse horizontal bracing, lower chord longitudinal horizontal bracing, and skylight frame bracing. Horizontal bracing bears gable wind loads and crane transverse horizontal braking forces, transferring them to the column bracing. It also ensures the in-plane stiffness of the roof, preventing buckling. Common forms are cross round steel or angle steel, installed in the first or second bays at both ends of a temperature section.

Technical Specifications

Parameter Specification
Layout Position Roof truss upper/lower chord planes, arranged along bays
Common Forms Cross round steel, cross angle steel, crisscross
Round Steel Diameter commonly φ20, φ25)
Angle Steel Spec L50×5~L90×6
Material Q235B
Setup Principle First or second bay at both ends of the temperature section
Tensioning Device Round steel bracing equipped with turnbuckles
Connection Bolted to the roof truss gusset plates
Function Transfer roof horizontal forces, ensure roof in-plane stiffness
Execution Standard GB 50017, GB 51022

Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Ensures roof in-plane stiffness: Turns the roof into a rigid disc, effectively transferring horizontal forces. Affects roof truss lower chord headroom: Cross bracing may affect pipeline layouts and requires coordination.
Transfers gable wind loads: Gable wind loads are transferred to column bracing via horizontal bracing. Tensioning must be controlled: Slack means failure; must be tensioned during installation.
Material-saving: Cross round steel is designed for tension, using very little steel. Numerous gusset plates: Every panel point has gusset plates, demanding heavy fabrication work.
Flexible layout: Can be adjusted according to doors and skylight positions. Temperature section setup: Must be arranged at both ends of the temperature section without omission.
Simple installation: Bolted connection, tensioned via turnbuckles. Rust risk: Round steel is thin and must be galvanized for anti-corrosion.

Frequently Asked Questions

What is the function of horizontal bracing?

Ensures roof in-plane stiffness, transfers gable wind loads and crane transverse braking forces.

Horizontal bracing + column bracing + Eave Strut Purlin form a spatial stability system.

commonly cross round steel Φ20~φ40, or cross angle steel.

The first or second bay at both ends of a temperature section.

Round steel cross bracing only bears tension; if slack, it cannot transfer forces promptly.

Skylight frames also need bracing, coordinated with roof truss lower chord bracing.

Horizontal bracing uses a crossed layout to transfer horizontal forces; Eave Strut Purlin are longitudinal to reduce compressive effective length.

No, omitting it makes the roof geometrically variable, lacking seismic and wind resistance.

Bolted via bolt holes on the roof truss gusset plates.

Hot-dip galvanizing or anti-rust paint + topcoat.

High-strength threaded sag rods supplied for a steel truss

Steel Truss Sag Rod

Sag rods (Eave Strut Purlin) are slender round steel tension members installed in the roof and wall girt systems of lightweight steel structures. They connect adjacent purlins or wall girts to reduce the out-of-plane effective length of the members, preventing purlins (or girts) from lateral bending and torsional deformation under wind loads, dead weight, and roof loads. Sag rods typically use HPB300 round steel with common diameters of φ12 or φ14, connected to the purlin web via bending or threaded ends with bolts. Diagonal sag rods and struts are usually installed at the ridge of double-pitch roofs to form a stable geometric invariable triangular system.

Technical Specifications

Parameter Specification
Common Materials HPB300 round steel (Q235)
Diameter commonly φ12)
Layout Spacing Based on purlin span: 4~6m generally 1 row, 6~9m generally 2 rows, above 9m generally 3 rows.
Connection Method Threaded ends, bolted to purlin web
Accessories Diagonal sag rod, steel purlin spacer tube (tube)
Installation Position Near the upper flange or center of the purlin web
Tensioning Requirements Must be pulled straight and tensioned during installation; no slack allowed
Anti-corrosion Treatment Hot-dip galvanizing or anti-rust paint
Installation Tools Wrench, tensioner
Execution Standard GB 51022

Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Simple structure: Round steel sag rods are easy to source and low cost. Tension degree must be controlled: Too loose provides no support; too tight may deform the purlins.
Significantly improves purlin stability: Reduces the out-of-plane effective length of purlins, preventing flexural-torsional buckling. Rust risk: Slender round steel easily rusts; requires galvanizing or painting and maintenance.
Convenient installation: Threaded ends, on-site bolting, fast construction. Connection nodes prone to loosening: Nuts may loosen under long-term vibration; regular checks needed.
Adjustable: Sag rod tightness can be finely adjusted via nuts. Densification needed in high-wind areas: Steep slopes and large wind suction zones require denser sag rod spacing.
Mature accessory system: Forms a complete bracing system with steel purlin spacer tube, diagonal sag rods, and struts. Cannot bear compression: Sag rods can only bear tension; compression zones require steel purlin spacer tubes.

Frequently Asked Questions

What is the function of a sag rod?

Connects adjacent purlins, reduces purlin out-of-plane effective length, and prevents lateral buckling and torsion.

Commonly HPB300 round steel, diameter φ12~φ14.

Threaded ends pass through the purlin web and are tightened with double nuts.

Sag rods bear tension; struts (steel purlin spacer tube) bear both tension and compression, used at ridges and eaves.

Based on span: 4~6m usually 1 row, 6~9m usually 2 rows, >9m usually 3 rows.

Generally bolted; welding is not recommended to avoid damaging the galvanized layer and purlins.

Retighten the nuts, or replace if necessary.

Yes, wall girts (wall purlins) also need sag rods to ensure out-of-plane stability.

Set at both sides of the ridge and eaves, forming triangular stable units with struts.

Hot-dip galvanizing is preferred, or two coats of anti-rust paint + topcoat.

Precision-cut spacer tubes between back-to-back purlins supplied for a steel truss

Steel Truss Purlin Spacer Tube

steel purlin spacer tube are short steel tubes placed over round steel sag rods in lightweight steel structures. Together with the sag rods, they form struts used in areas subjected to both tension and compression (such as roof ridges, eaves, and steep-sloped roofs). steel purlin spacer tube are generally made of Q235 welded steel pipes or galvanized steel pipes, with common diameters of φ32×2.0~2.5, and lengths equal to the purlin spacing. steel purlin spacer tube convert the sag rod system from a tension-only system into a two-force member capable of bearing compression, ensuring the geometric invariability of the roof.

Technical Specifications

Parameter Specification
Common Specifications φ32×2.0~2.5
Material Q235 welded steel pipe or galvanized steel pipe
Length Equal to purlin spacing (approx. 0.5~1.5m)
Installation Position Roof ridges, eaves, and sag rod locations requiring compression resistance
Relationship with Sag Rod Sleeved over the round steel sag rod, with both ends pressed tightly against the purlins
Connection Method Sag rod passes through the sleeve, locked by nuts at both ends
Anti-corrosion Treatment Hot-dip galvanizing or anti-rust paint
Function Enables the sag rod system to bear both tension and compression
Accessories Round steel sag rod, diagonal sag rod
Execution Standard GB 51022

Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Simple structure: Ordinary steel pipe slipped over the sag rod, low cost. Exact length required: Too long cannot fit tightly, too short leaves a gap; requires on-site measurement.
Enables sag rods to bear compression: Solves the issue of round steel sag rods not bearing compression, forming stable struts. Both ends must press tightly: After installation, both ends must tightly fit the purlin webs without gaps.
Convenient installation: Installed synchronously with sag rods, no extra welding needed. Rust risk: Thin pipe walls require galvanizing for anti-corrosion.
Standardized: Specifications match purlin spacing, easy selection. Gap with sag rod: The inner diameter of the sleeve should be 2~4mm larger than the sag rod for easy insertion.
Improves overall roof stiffness: Forms a geometric invariable system together with sag rods and diagonal sag rods. Cannot replace diagonal sag rods: Sleeve struts still need to cooperate with diagonal sag rods to form a complete system.

Frequently Asked Questions

What is a steel purlin spacer tube?

A short steel purlin spacer tube over a round steel sag rod, turning the sag rod system into a strut that can bear compression.

Commonly φ32×2.0~2.5 galvanized steel pipes.

The sag rod passes through the sleeve; the sleeve ends press tightly against purlin webs, and sag rod ends are locked with nuts.

Ridges, eaves, and other areas subjected to both tension and compression.

Equal to the purlin spacing, generally 0.5~1.5m.

No, ordinary round steel sag rods can only bear tension; compression zones must have sleeve struts.

Hot-dip galvanizing is preferred, or anti-rust paint.

No, the sag rod nuts lock tightly to make the sleeve press tight.

At the ridge, diagonal sag rods + sleeve struts form a triangular stable unit.

No, steel purlin spacer tube only serve as struts and do not bear roof loads.

Heavy-duty galvanised or stainless steel gutters supplied for a steel truss

Steel Truss Steel Gutters

Steel Gutters are metal trench components arranged at the edges of plant and building roofs to collect and discharge rainwater, usually set along the eaves or as internal valley Steel Gutters, connecting to downspouts via scuppers. By material, they can be divided into galvanized steel gutters, stainless steel gutters (201/304), and color-coated steel gutters; by layout, into external gutters (hung outside eaves) and internal gutters (embedded within the roof). Gutter design must consider catchment area, rainfall intensity, bottom slope, and scupper sizes to ensure no overflow, backflow, or leakage during rainstorms.

Technical Specifications

Parameter Specification
Common Materials Galvanized steel, Stainless steel 304/316, Color-coated steel sheet
Plate Thickness mm ~ 4.0mm
Section Forms Rectangular, trapezoidal, curved
Common Dimensions Width 300~1200mm, Depth 150~800mm
Slope Gutter bottom longitudinal slope ≥0.5% (sloping towards scupper)
Scupper Spacing m (calculated based on rainfall volume)
Connection Welded or seamed, overlap ≥100mm
Anti-corrosion Stainless steel needs no anti-corrosion; galvanized/color steel maintained per environment
Accessories Scuppers, downspouts, gutter brackets, end caps
Execution Standard GB 50015 "Standard for design of building water supply and drainage", GB 51022

Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Organized drainage: Prevents rainwater from randomly washing over walls and foundations. Welds prone to leakage: Poor on-site welding leads to leaks; requires full welding and water tightness tests.
Corrosion-resistant materials: Stainless steel gutters can be used in humid and corrosive environments. Cold regions need freeze protection: Internal gutters in cold areas require insulation to prevent freezing.
Factory prefabrication: Manufactured in segments, assembled on-site, fast construction. Blockage risks: Leaves and dust easily block scuppers; requires regular cleaning.
Neat appearance: Metal gutters coordinate aesthetically with building facades. Corrosive environments demand specific materials: Chemical/coastal areas must use 316 stainless steel or thickened galvanization.
Customizable: Cross-section dimensions and forms customized per architectural and drainage needs. Thermal expansion must be considered: Long gutters need expansion joints or sliding brackets.

Frequently Asked Questions

What materials are used for Steel Gutters?

Commonly galvanized steel sheet, stainless steel 304/316, color-coated steel sheet.

Generally 1.0~4.0mm; large-span Steel Gutters use thick plates or additional gutter brackets.

External Steel Gutters are hung outside eaves; internal Steel Gutters are embedded inside the roof, flanked by roof surfaces.

The longitudinal bottom slope is generally ≥0.5%, sloping towards the scupper.

Generally ≤30m or one per bay, calculated by local rainfall intensity and catchment area.

Water tightness tests are conducted after full welding, followed by exterior anti-corrosion or waterproof coatings.

Stainless steel is exempt; galvanized sheets get topcoats; chemical zones use 316 stainless steel.

Internal Steel Gutters need insulation to prevent frost heaving cracks and frozen scuppers.

Lengths exceeding 30m require expansion joints or one end with a sliding bracket.

Clean welds, re-weld, apply waterproof coating, or replace plate segments if necessary.

Eave Strut Purlin

Steel Truss Eave Strut Purlin

Eave Strut Purlin (struts) are members arranged longitudinally along the plant, connecting the ends of adjacent rigid frames (or roof trusses). Together with column bracing and roof horizontal bracing, they form a spatial geometric invariable system. Eave Strut Purlin can be divided into rigid Eave Strut Purlin (can bear both tension and compression, commonly circular tubes or H-beams) and flexible Eave Strut Purlin (can only bear tension, commonly round steel or angle steel). The main function of Eave Strut Purlin is to transfer longitudinal horizontal forces, reduce the effective length of compressive members, and ensure the lateral stability of rigid frame ends. They are usually installed at roof truss ends, ridges, column tops, and column base elevations.

Technical Specifications

Parameter Specification
Common Sections Circular tube φ89×3~φ159×6, H-beam, round steel
Material Q235B, Q355B
Classification Rigid tie rod (compression), Flexible tie rod (tension)
Layout Position Roof truss ends, ridges, column tops, corners
Connection Method Bolted to the connection plate at the rigid frame end
Function Transfers longitudinal horizontal forces, reduces effective length of compressive members
Spacing Corresponds to bracing bays, generally every alternate bay
Accessories Forms a spatial system together with horizontal bracing and column bracing
Anti-corrosion Galvanized or painted
Execution Standard GB 50017, GB 51022

Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Forms spatial stability system: Eave Strut Purlin + bracing make the plant a geometrically invariable spatial structure. Rigid Eave Strut Purlin have larger sections: Compressive Eave Strut Purlin must control slenderness ratios, needing larger sections than tension members.
Reduces compressive effective length: Provides lateral fulcrums for rigid frame ends and roof truss end compression members. Numerous gusset plate welds: End gusset plates require many welds.
Flexible layout: Can be adjusted based on roof modeling and doorway positions. Affects headroom: Ridge and eaves Eave Strut Purlin may occupy a small amount of space.
Material saving: Flexible Eave Strut Purlin only require round steel. Tensioning must be controlled: Flexible round steel Eave Strut Purlin must be tensioned during installation.
Convenient installation: Bolted at both ends, fast construction. Cannot be omitted: Omission leads to a geometrically variable system.

Frequently Asked Questions

What is Eave Strut Purlin?

A member arranged longitudinally connecting adjacent rigid frames, divided into rigid and flexible Eave Strut Purlin.

Rigid Eave Strut Purlin can bear compression (circular tubes/H-beams); flexible Eave Strut Purlin only bear tension (round steel/angle steel).

Roof truss ends, ridges, column tops, and column base elevations.

Eave Strut Purlin connect adjacent column rows, working with column bracing to form a longitudinal stability system.

Rigid Eave Strut Purlin commonly use circular tubes φ89×4~φ159×6; flexible Eave Strut Purlin use round steel.

Both ends are bolted to the gusset plates at the rigid frame ends.

Omission deprives the rigid frame ends of lateral support, making the system geometrically variable.

Yes, tensioned using turnbuckles.

Eave Strut Purlin run longitudinally connecting rigid frames; sag rods connect purlins to reduce their out-of-plane effective length.

Galvanizing or anti-rust paint + topcoat.

Qualification Certificate

Your projects are protected by world-class standards. From CE (EN 1090) to ISO 9001, our qualifications are not just paper—they are the rigorous daily reality on our shop floor.

AISCCEOTCInternational Welder
ISO 9001 Quality Management System

Have drawings or a BOQ ready?

SynJect
SynJect factory
SynJect factory
SynJect factory
Kunlun Lu
SynJect factory
SynJect factory
SynJect factory
SynJect factory
SynJect factory

SynJect:Scale. Precision. Certainty.

SYNJECT delivers comprehensive steel structure solutions engineered for the global value chain. From investors seeking ROI to engineers demanding exact compliance, we transform complex blueprints into robust realities—on time and without friction.

From Blueprint to Site. Zero Friction.

Detailed Engineering & Shop Drawing DevelopmentNesting & Material OptimizationRaw Material Incoming InspectionCNC Cutting & Edge PreparationWeld Distortion StraighteningNon-Destructive Testing (NDT)Trial Assembly & Shop AlignmentSurface Preparation & Protective CoatingMeasure Paint Film ThicknessFinal Quality Inspection & CertificationExport Packaging & Logistics ProtectionGlobal Field Erection & Site Management
Stage.01

Detailed Engineering

Utilizing advanced BIM platforms such as Tekla Structures, detailed 3D modeling and shop drawings are executed strictly in compliance with AISC 360 or Eurocode 3 (EN 1993). Connection designs are rigorously verified, with manufacturing drawings generated to ISO 2768-m tolerance standards. 100% clash detection with primary architectural and MEP systems is performed to ensure zero structural conflicts during field erection.

STANDARDAISC 360 / EN 1993
METRIC VALUETolerance ±0.01mm
Stage.02

Nesting & Material Optimization

Intelligent nesting layouts are performed using advanced software like FastCAM/SigmaNEST in accordance with EN 10029 / ASTM A6 dimensional standards. Accounting for cutting kerf (2mm–5mm depending on plate thickness) and thermal contraction allowances, raw material utilization exceeds 92%. Offcuts are digitally barcode-tracked to ensure 100% mill test report (MTR) traceability.

STANDARDEN 10029 / ASTM A6
METRIC VALUEUtilization 95%
Stage.03

Raw Material Incoming Inspection

All structural steel (Q355B/C/D, ASTM A572 Gr.50, S355JR/J2) must be accompanied by EN 10204 3.1 Mill Test Reports (MTR). Incoming quality control conducts 100% dimensional and visual inspections under ASTM A6 / EN 10029, verifying thickness tolerances (Class A/B) and internal lamination integrity via Ultrasonic Testing (UT) to ASTM A435. Chemical composition and mechanical properties are spot-verified by accredited 3rd-party labs.

STANDARDEN 10204 3.1 / ASTM A435
METRIC VALUEClass A/B and ASTM A435
Stage.04

CNC Cutting & Edge Preparation

Plate profiling and component cutting are executed via CNC oxy-fuel, high-definition plasma, and multi-kW fiber laser equipment. Cut surface quality strictly complies with EN ISO 9013 for perpendicularity and surface roughness ±2.5°, Range 3/4 tolerance. Multi-axis CNC beveling machines execute weld prep bevel angles within ±2.5° and root face dimensions within ±1.0 mm.

STANDARDEN ISO 9013
METRIC VALUERa ≤12.5μm
Stage.05

Weld Distortion Straightening

Welding is performed exclusively by AWS D1.1 or EN ISO 9606 certified welders using qualified Welding Procedure Specifications (WPS) supported by Procedure Qualification Records (PQR) per AWS D1.1 / ISO 15614. Submerged Arc Welding (SAW) and Flux-Cored Arc Welding (FCAW) dominate Complete Joint Penetration (CJP) and fillet welds. Heat input is strictly controlled, achieving weld quality levels conforming to ISO 5817 Quality Level B or AWS D1.1 standards.

STANDARDAWS D1.1 / EN ISO 9606
METRIC VALUEISO 5817Level B
Stage.06

Non-Destructive Testing (NDT)

Post-weld angular distortion, camber, and sweep are rectified using automated hydraulic flange straighteners and controlled thermal flame straightening. Heating temperatures for High-Strength Low-Alloy (HSLA) steels are strictly maintained between 600℃ - 650℃ (air-cooled, zero water quenching) to prevent microstructural degradation. Post-straightening straightness tolerances meet ±3 mm, conforming to EN 1090-2 Execution Class 2 (EXC2) and AISC COSP standards.

STANDARDEN 1090-2 EXC2 / AISC COSP
METRIC VALUETolerances ±3 mm
Stage.07

Trial Assembly & Shop Alignment

NDT protocols are operated by ISO 9712 / ASNT Level II certified NDT personnel. 100% of critical Complete Joint Penetration (CJP) welds undergo Ultrasonic Testing (UT per ISO 17640 / ASTM E164) or Magnetic Particle Testing (MT per ISO 17638 / ASTM E709). Radiographic Testing (RT) is applied as requested for heavy sections. Weld acceptance conforms strictly to ISO 11666 Acceptance Level 1 or AWS D1.1 criteria.

STANDARDISO 11666 Level 1 / AWS D1.1
METRIC VALUE100% UT
Stage.08

Surface Preparation & Protective Coating

Complex geometries, long-span trusses, and heavy framing undergo 1:1 physical trial assembly or high-precision 3D laser scanning virtual assembly per EN 1090-2 / AISC requirements. Bolt hole alignment is verified (≥ 95% free-pass rate for high-strength bolts), and critical dimensions (span, camber, 3D spatial alignment) are verified within tight tolerance limits (±2.0 mm) to eliminate site fitting risks.

STANDARDAISC / EN 1090-2
METRIC VALUETolerance ±2.0 mm
Stage.09

Measure Paint Film Thickness

Structural members undergo automated shot blasting to achieve SSPC-SP10 / NACE No. 2 / ISO 8501-1 Sa 2.5 cleanliness, with a surface profile (anchor depth) of 45–75μm. High-performance protective coatings are applied using airless spray technology in compliance with ISO 12944 (C3 to CX corrosive environments), featuring Inorganic/Organic Zinc-Rich Epoxy Primers, Epoxy Micaceous Iron Oxide Intermediate coats, and Polyurethane/Fluorocarbon Topcoats. Dry Film Thickness (DFT) is verified using calibrated magnetic gauges adhering strictly to the 90/10 rule.

STANDARDISO 8501-1 Sa 2.5 / ISO 12944
METRIC VALUE45 - 75μm
Stage.10

Final Quality Inspection & Certification

Final Quality Control (FQC) performs a comprehensive holistic audit, inspecting paint aesthetics (zero runs, pinholes, sagging), critical geometry, bolt hole pitches, and laser/stenciled component mark traceability. A complete Manufacturing Data Report (MDR)—comprising MTRs, NDT records, coating inspection logs, and Certificates of Conformance—is compiled to support CE Marking (DoP under EN 1090) and AISC final acceptance.

STANDARDEN 1090 / AISC
METRIC VALUEQA/QC Final Release
Stage.11

Export Packaging & Logistics Protection

Protective packaging is engineered for containerized (40HQ/OT/FR) and breakbulk ocean freight under heavy maritime transit conditions. Structural members are bundled on heavy-duty steel skids with high-tensile steel strapping. Machined connections and contact surfaces are wrapped with VCI anti-corrosion film, EPE foam padding, and heavy rubber cushions. All timber packing complies fully with ISPM 15 phytosanitary standards and IMO Cargo Stowage and Securing (CSS) rules.

STANDARDISPM 15 / IMO CSS
METRIC VALUE40HQ/OT/FR
Stage.12

Global Field Erection & Site Management

We deliver international site erection supervision and turnkey EPCM construction services adhering to OSHA 1926 safety protocols, AISC COSP, and EN 1090-2 erection standards. Field teams, led by multilingual HSE and QA/QC engineers, utilize high-precision total stations to maintain structural plumbness within H/1000 (≤25mm max). High-Strength Structural Bolting is executed via calibrated Wrench or Turn-of-Nut methods with 100% torque audit documentation.

STANDARDOSHA 1926 / EN 1090-2
METRIC VALUE≤ H/1000

Get Your 24-Hour BOQ and Cost Plan

See how much steel tonnage and ocean freight you can save before fabrication begins

8–15%

Steel Weight Savings

1:1 Tekla 3D modeling optimizes beam-column ratios to eliminate redundant material costs.

0.0mm

Zero-Clash Code Verification

Checked against EN 1090 and local wind/seismic loads.

100%

Engineer-to-Engineer Review

Verified by our lead engineers—Zero pushy sales calls, Just actionable data and factory price.

CE EN 1090-1•ISO 9001•ISO 14001•ISO 45001

Engineering & Inquiry Desk

Lead Engineers Online

Drawings