Home / Products / LGS House / Connection & Foundation

Connection & Foundation

Galvanized U-section bottom track on a damp-proof course with anchor bolts, C-section stud and corner bracket

Connectors and anchor details transfer uplift from the frame into the foundation. We issue the anchor layout and reaction loads so the local engineer can design the footing.

What we fabricate in this sub-system

  • Brackets & Fasteners
  • Foundation System
Galvanized angle brackets, tension strap, joist hanger and self-drilling screws laid out on a steel bench

Brackets & Fasteners

In an LGS frame the connections are all small: screws, straps, hold-downs and joist hangers. Individually they are trivial; collectively they decide whether the house resists uplift. The failure mode is not a broken screw but a missing or wrongly specified one, which is why the schedule matters more than the hardware.

Technical Specifications

Parameter Specification
Types Self-drilling screws, strap bracing, hold-down brackets, joist hangers
Screw Material Galvanized or stainless, class per exposure
Screw Size M4.8–M6.3 typical, length per connection
Hold-downs Galvanized steel brackets at uplift points
Straps Galvanized tension straps across panel joints
Corrosion Class 3 minimum inland, Class 4 coastal
Torque Per manufacturer, checked with a clutch setting
Schedule Connection schedule on the drawing, not by habit
Testing Pull-out test on a sample where specified
Standard AS/NZS 4600, AS 3566 for screws

Dimensions and grades shown are the range we fabricate routinely. Final values are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Every connection has a designed capacity The schedule exists because a longer screw does not mean a stronger connection — pull-out depends on thread engagement in thin steel, which has an optimum.
Coating class decides service life Class 3 screws in a coastal house will fail at the head within years. The class is specified by exposure, not by what is in the van.
Missing connectors are the real risk A house with all the right brackets is fine; a house missing two hold-downs at a corner is not. The packing list and the drawing are the control.

Frequently Asked Questions

What screw coating is needed near the coast?

Class 4 or stainless. Class 3 galvanized is for inland sheltered sites; at the coast the head corrodes first and the connection is lost before the frame is.

From the connection schedule: it depends on the number of steel layers being joined. A screw that is too long protrudes; too short and it does not develop pull-out.

Where the design requires uplift resistance, yes — typically at corners, at wall ends and on multi-storey frames. The location and capacity come from the wind design.

By setting the clutch on the driver and checking on a sample. Over-driving strips the thread in thin steel, and the connection looks complete but is not.

Only with equivalent tested capacity and coating class. Substituting a similar-looking bracket is how a designed connection becomes an untested one.

Galvanized bottom track fixed to a concrete slab with anchor bolts, square washers and a corner hold-down bracket

Foundation System

The foundation is where an LGS house meets the ground, and it is the interface most often left to someone else. We do not design the footing — we issue the anchor layout and the reaction loads so the local engineer can. What matters is that the anchors line up with the bottom track within tolerance, because a steel frame has no give in it.

Technical Specifications

Parameter Specification
Types Concrete slab-on-grade, strip footing, pad footing, suspended floor
Anchor Type Cast-in anchor bolts or post-fixed mechanical anchors
Anchor Spacing Per design, typically at studs and corners
Base Detail Bottom track fixed through a damp-proof course
Reaction Loads Uplift and shear issued by us for footing design
Tolerance Anchor position ± 5 mm, level ± 3 mm over 3 m
Termite & Damp Physical barrier and DPC under the track
Flood Level Floor level set above local flood requirement
Standard EN 1992 / local code for the footing itself

Dimensions and grades shown are the range we fabricate routinely. Final values are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Anchor tolerance is the whole game A steel bottom track has no flexibility. If the anchors are 10 mm out, the frame will not go down — which is why we issue a setting-out drawing, not just a load schedule.
We give reactions, you design the footing Local engineers design to local ground conditions and code. Our job is to supply the uplift and shear values, and to hold the anchor positions.
Slab or suspended floor changes everything A slab is cheaper; a suspended floor suits flood-prone or sloping sites. The choice affects the frame base detail, so it is settled before fabrication.

Frequently Asked Questions

Do you design the foundation?

No. We issue the anchor layout, the base detail and the reaction loads; the footing itself is designed by the local engineer to local ground conditions and code. That is the arrangement that keeps the design responsibility where the liability sits.

About ± 5 mm in position and ± 3 mm in level over 3 m. Steel does not accommodate error the way timber does, so the setting-out drawing has to be followed.

Yes, with mechanical or chemical anchors into the cured concrete, provided the capacity is verified. Cast-in is preferred because post-fixing near the slab edge risks hitting reinforcement.

With a damp-proof course under the bottom track and a physical termite barrier where required. The track is not in direct contact with the slab surface.

Use a suspended floor with the frame set above the flood level, and detail the underfloor ventilation. Raising the floor changes the anchor detail, so it must be decided early.

Qualification Certificate

Your projects are protected by world-class standards. From CE (EN 1090) to ISO 9001, our qualifications are not just paper—they are the rigorous daily reality on our shop floor.

AISCCEOTCInternational Welder
ISO 9001 Quality Management System

Have drawings or a BOQ ready?

SynJect
SynJect factory
SynJect factory
SynJect factory
Kunlun Lu
SynJect factory
SynJect factory
SynJect factory
SynJect factory
SynJect factory

SynJect:Scale. Precision. Certainty.

SYNJECT delivers comprehensive steel structure solutions engineered for the global value chain. From investors seeking ROI to engineers demanding exact compliance, we transform complex blueprints into robust realities—on time and without friction.

From Blueprint to Site. Zero Friction.

Detailed Engineering & Shop Drawing DevelopmentNesting & Material OptimizationRaw Material Incoming InspectionCNC Cutting & Edge PreparationWeld Distortion StraighteningNon-Destructive Testing (NDT)Trial Assembly & Shop AlignmentSurface Preparation & Protective CoatingMeasure Paint Film ThicknessFinal Quality Inspection & CertificationExport Packaging & Logistics ProtectionGlobal Field Erection & Site Management
Stage.01

Detailed Engineering

Utilizing advanced BIM platforms such as Tekla Structures, detailed 3D modeling and shop drawings are executed strictly in compliance with AISC 360 or Eurocode 3 (EN 1993). Connection designs are rigorously verified, with manufacturing drawings generated to ISO 2768-m tolerance standards. 100% clash detection with primary architectural and MEP systems is performed to ensure zero structural conflicts during field erection.

STANDARDAISC 360 / EN 1993
METRIC VALUETolerance ±0.01mm
Stage.02

Nesting & Material Optimization

Intelligent nesting layouts are performed using advanced software like FastCAM/SigmaNEST in accordance with EN 10029 / ASTM A6 dimensional standards. Accounting for cutting kerf (2mm–5mm depending on plate thickness) and thermal contraction allowances, raw material utilization exceeds 92%. Offcuts are digitally barcode-tracked to ensure 100% mill test report (MTR) traceability.

STANDARDEN 10029 / ASTM A6
METRIC VALUEUtilization 95%
Stage.03

Raw Material Incoming Inspection

All structural steel (Q355B/C/D, ASTM A572 Gr.50, S355JR/J2) must be accompanied by EN 10204 3.1 Mill Test Reports (MTR). Incoming quality control conducts 100% dimensional and visual inspections under ASTM A6 / EN 10029, verifying thickness tolerances (Class A/B) and internal lamination integrity via Ultrasonic Testing (UT) to ASTM A435. Chemical composition and mechanical properties are spot-verified by accredited 3rd-party labs.

STANDARDEN 10204 3.1 / ASTM A435
METRIC VALUEClass A/B and ASTM A435
Stage.04

CNC Cutting & Edge Preparation

Plate profiling and component cutting are executed via CNC oxy-fuel, high-definition plasma, and multi-kW fiber laser equipment. Cut surface quality strictly complies with EN ISO 9013 for perpendicularity and surface roughness ±2.5°, Range 3/4 tolerance. Multi-axis CNC beveling machines execute weld prep bevel angles within ±2.5° and root face dimensions within ±1.0 mm.

STANDARDEN ISO 9013
METRIC VALUERa ≤12.5μm
Stage.05

Weld Distortion Straightening

Welding is performed exclusively by AWS D1.1 or EN ISO 9606 certified welders using qualified Welding Procedure Specifications (WPS) supported by Procedure Qualification Records (PQR) per AWS D1.1 / ISO 15614. Submerged Arc Welding (SAW) and Flux-Cored Arc Welding (FCAW) dominate Complete Joint Penetration (CJP) and fillet welds. Heat input is strictly controlled, achieving weld quality levels conforming to ISO 5817 Quality Level B or AWS D1.1 standards.

STANDARDAWS D1.1 / EN ISO 9606
METRIC VALUEISO 5817Level B
Stage.06

Non-Destructive Testing (NDT)

Post-weld angular distortion, camber, and sweep are rectified using automated hydraulic flange straighteners and controlled thermal flame straightening. Heating temperatures for High-Strength Low-Alloy (HSLA) steels are strictly maintained between 600℃ - 650℃ (air-cooled, zero water quenching) to prevent microstructural degradation. Post-straightening straightness tolerances meet ±3 mm, conforming to EN 1090-2 Execution Class 2 (EXC2) and AISC COSP standards.

STANDARDEN 1090-2 EXC2 / AISC COSP
METRIC VALUETolerances ±3 mm
Stage.07

Trial Assembly & Shop Alignment

NDT protocols are operated by ISO 9712 / ASNT Level II certified NDT personnel. 100% of critical Complete Joint Penetration (CJP) welds undergo Ultrasonic Testing (UT per ISO 17640 / ASTM E164) or Magnetic Particle Testing (MT per ISO 17638 / ASTM E709). Radiographic Testing (RT) is applied as requested for heavy sections. Weld acceptance conforms strictly to ISO 11666 Acceptance Level 1 or AWS D1.1 criteria.

STANDARDISO 11666 Level 1 / AWS D1.1
METRIC VALUE100% UT
Stage.08

Surface Preparation & Protective Coating

Complex geometries, long-span trusses, and heavy framing undergo 1:1 physical trial assembly or high-precision 3D laser scanning virtual assembly per EN 1090-2 / AISC requirements. Bolt hole alignment is verified (≥ 95% free-pass rate for high-strength bolts), and critical dimensions (span, camber, 3D spatial alignment) are verified within tight tolerance limits (±2.0 mm) to eliminate site fitting risks.

STANDARDAISC / EN 1090-2
METRIC VALUETolerance ±2.0 mm
Stage.09

Measure Paint Film Thickness

Structural members undergo automated shot blasting to achieve SSPC-SP10 / NACE No. 2 / ISO 8501-1 Sa 2.5 cleanliness, with a surface profile (anchor depth) of 45–75μm. High-performance protective coatings are applied using airless spray technology in compliance with ISO 12944 (C3 to CX corrosive environments), featuring Inorganic/Organic Zinc-Rich Epoxy Primers, Epoxy Micaceous Iron Oxide Intermediate coats, and Polyurethane/Fluorocarbon Topcoats. Dry Film Thickness (DFT) is verified using calibrated magnetic gauges adhering strictly to the 90/10 rule.

STANDARDISO 8501-1 Sa 2.5 / ISO 12944
METRIC VALUE45 - 75μm
Stage.10

Final Quality Inspection & Certification

Final Quality Control (FQC) performs a comprehensive holistic audit, inspecting paint aesthetics (zero runs, pinholes, sagging), critical geometry, bolt hole pitches, and laser/stenciled component mark traceability. A complete Manufacturing Data Report (MDR)—comprising MTRs, NDT records, coating inspection logs, and Certificates of Conformance—is compiled to support CE Marking (DoP under EN 1090) and AISC final acceptance.

STANDARDEN 1090 / AISC
METRIC VALUEQA/QC Final Release
Stage.11

Export Packaging & Logistics Protection

Protective packaging is engineered for containerized (40HQ/OT/FR) and breakbulk ocean freight under heavy maritime transit conditions. Structural members are bundled on heavy-duty steel skids with high-tensile steel strapping. Machined connections and contact surfaces are wrapped with VCI anti-corrosion film, EPE foam padding, and heavy rubber cushions. All timber packing complies fully with ISPM 15 phytosanitary standards and IMO Cargo Stowage and Securing (CSS) rules.

STANDARDISPM 15 / IMO CSS
METRIC VALUE40HQ/OT/FR
Stage.12

Global Field Erection & Site Management

We deliver international site erection supervision and turnkey EPCM construction services adhering to OSHA 1926 safety protocols, AISC COSP, and EN 1090-2 erection standards. Field teams, led by multilingual HSE and QA/QC engineers, utilize high-precision total stations to maintain structural plumbness within H/1000 (≤25mm max). High-Strength Structural Bolting is executed via calibrated Wrench or Turn-of-Nut methods with 100% torque audit documentation.

STANDARDOSHA 1926 / EN 1090-2
METRIC VALUE≤ H/1000

Get Your 24-Hour BOQ and Cost Plan

See how much steel tonnage and ocean freight you can save before fabrication begins

8–15%

Steel Weight Savings

1:1 Tekla 3D modeling optimizes beam-column ratios to eliminate redundant material costs.

0.0mm

Zero-Clash Code Verification

Checked against EN 1090 and local wind/seismic loads.

100%

Engineer-to-Engineer Review

Verified by our lead engineers—Zero pushy sales calls, Just actionable data and factory price.

CE EN 1090-1•ISO 9001•ISO 14001•ISO 45001

Engineering & Inquiry Desk

Lead Engineers Online

Drawings
Drawings

🔒 100% Private and Secure, No Spam