Home / Resources / Steel Building Design Codes

Steel Building Design Codes by Country: A 2026 Cross-Reference

A pre-engineered steel building package usually crosses two code regimes at once: the standard the buyer’s engineer of record designs to, and the standard the fabrication shop works to. This reference maps the governing steel building design codes across 13 markets, then cross-maps the four areas that actually cause submittal rejections — material grades, execution classes, bolting systems and corrosion protection.

How to read this reference

Three different parties own three different documents on a single PEB order. The engineer of record selects the design and loading codes and seals the calculations. The fabricator works to a welding and execution standard. The third-party inspector applies an acceptance criteria that may come from a fourth document entirely. Any steel building design codes table that lists only the member check therefore answers a third of the question.

For example, a warehouse in Jazan may be designed to SBC 301 loads and SBC 306 member checks, fabricated under EN 1090-2 execution class EXC2, welded to ISO 3834-2 quality requirements, and inspected against EN ISO 5817 level C. Four standards, one building. None of them is optional, and none of them substitutes for another.

Currency of this table. Editions were checked against publisher catalogues in November 2026. Codes are amended on their own cycles and national annexes diverge from the base Eurocode text, so confirm the governing edition with the authority having jurisdiction before you fix a design basis. Where an edition is amended annually we name the standard family rather than risk a stale year.

Steel building design codes by country

Market Structural steel design Loading Cold-formed steel Seismic
United States AISC 360-22; AISC 303-22 for standard practice; MBMA Metal Building Systems Manual (2024 ed.) for PEMB systems ASCE 7-22; IBC 2024 AISI S100-16 (R2020); AISI S240-20 ASCE 7-22 Chapters 11–23
Canada CSA S16:24 NBCC 2020, Part 4 CSA S136 (AISI S100 harmonised) NBCC 2020, Part 4
Mexico NTC-Metálicas (current CDMX edition); AISC 360 on industrial projects NTC-Cargas AISI S100 NTC-Sismo
European Union EN 1993-1-1 with the relevant National Annex EN 1991-1-1 to 1-4 EN 1993-1-3 EN 1998-1
United Kingdom BS EN 1993-1-1 + UK National Annex; BS 5950 retained for existing structures BS EN 1991 BS EN 1993-1-3 BS EN 1998-1 + UK NA
China GB 50017-2017 GB 50009-2012 GB 50018-2002 GB 50011-2010 (2016 amendment)
India IS 800:2007 IS 875, Parts 1–5 IS 801:1975 IS 1893 (Part 1):2016
Australia / New Zealand AS 4100:2020 AS/NZS 1170.0 to 1170.3 AS/NZS 4600:2018 AS 1170.4, NZS 1170.5
Brazil ABNT NBR 8800:2008 ABNT NBR 8681:2003 ABNT NBR 14762:2010 ABNT NBR 15421:2006
Indonesia SNI 1729:2020 SNI 1727:2020 SNI 7971:2013 SNI 1726:2019
Philippines NSCP 2015, Vol. 1 (AISC 360-10 basis) NSCP 2015 NSCP 2015 / AISI S100 NSCP 2015
Saudi Arabia SBC 306 (2018), AISC 360 basis SBC 301 (2018), ASCE 7-16 basis AISI S100 SBC 301 (2018)
South Africa SANS 10162-1:2011 SANS 10160 series SANS 10162-2 SANS 10160 series

Three families of design philosophy

Most cross-border disputes trace back to one fact: the same member produces a different utilisation ratio under AISC, Eurocode and GB. AISC 360 uses nominal strength multiplied by a resistance factor φ. Eurocode 3 uses characteristic resistance divided by a partial factor γM. GB 50017 uses design values with its own partial factors. The target reliability indices behind those numbers are not identical, and the load factors feeding them differ too.

Consequently, a member designed to 95% utilisation under AISC 360 will usually not pass a Eurocode check unchanged, and a GB-optimised section will look over-designed to an ASCE 7 reviewer. The correct response is to re-run the member checks in the nominated code, not to convert the final number with a factor.

Steel grade cross-reference

Grade Standard Yield fy (MPa, t ≤ 16 mm) Tensile fu (MPa)
A36 ASTM A36/A36M 250 400–550
A992 ASTM A992/A992M 345–450 450 min.
A572 Gr. 50 ASTM A572/A572M 345 450 min.
S235JR / J0 / J2 EN 10025-2 235 360–510
S275JR / J0 / J2 EN 10025-2 275 430–580
S355JR / J0 / J2 / ML EN 10025-2 355 470–630
S420ML EN 10025-2 / -4 420 500–660
Q235B GB/T 700 235 370–500
Q355B / Q355D GB/T 1591 355 470–630
E250 (Fe 410W) IS 2062 250 410 min.
E350 (Fe 490W) IS 2062 350 490 min.
Grade 300 AS/NZS 3679.1 300 440
Grade 350 AS/NZS 3679.1 330–340 (by thickness) 450
SS400 JIS G3101 245 400–510
SN400B JIS G3136 235 400–510

Rules for substituting one grade for another

  • Yield strength is thickness-dependent. EN 10025 drops fy above 16 mm and again above 40 mm. Quoting 355 MPa for a 30 mm end plate on a European plate is wrong by roughly 10%. Check the thickness band before you release the BOM.
  • A992 has no direct overseas equivalent. It is a US wide-flange-specific specification with a minimum fy/fu ratio requirement that makes it weldable and ductile. Outside North America the usual substitutes are S355J2 or A572 Gr. 50, and both need an explicit equivalence note in the submittal.
  • Impact toughness is a separate purchase condition. The JR / J0 / J2 suffix is the Charpy designation, tested at +20 °C, 0 °C and −20 °C respectively. Cold-store or high-altitude projects routinely need J2 or ML. A grade certificate without the impact line is not a certificate of conformity.
  • Mill certificates must state the standard and the heat number. For structural steel in a CE-marked package, that means an inspection certificate to EN 10204 3.1, issued by the mill rather than the stockholder.

Execution and weld quality frameworks

This is where most overseas submittals fail. Each region regulates fabrication through a different concept, so a package built for one reviewer looks incomplete to another. The four frameworks below are not translations of one another; they attach responsibility differently.

Framework Applies in How it classifies the work Weld acceptance Default NDT expectation
AWS D1.1/D1.1M:2020 US, and contract-based projects elsewhere Statically or cyclically loaded; fracture-critical member (FCM) status assigned by the engineer Visual plus ultrasonic, acceptance by clause 6 100% UT on complete-joint-penetration groove welds in FCM; visual on all welds
AISC 360-22 Ch. N + AISC 303-22 US Splits quality assurance from quality control between EOR, fabricator and erector Refers to AWS D1.1 Fabricator holds an approved QC programme; AISC certification is voluntary but commonly specified
EN 1090-1 + EN 1090-2:2018 EU, UK, and adopted widely in the Gulf and North Africa Execution classes EXC1 to EXC4, derived from consequence class, service category and production category EN ISO 5817 quality levels B, C or D Percentage NDT rises with execution class and weld type; EXC3 and EXC4 approach full inspection on butt welds
GB 50205-2020 + GB 50661-2011 China, and Chinese-funded projects abroad Weld quality grades 一级, 二级, 三级 (Grade I, II, III) Ultrasonic testing to GB/T 11345 Grade I butt welds in tension are inspected at 100%; Grade II at 20%
AS/NZS 5131:2016 Australia, New Zealand Construction categories CC1 to CC4 AS/NZS 1554 series Inspection scope scales with construction category

What each framework actually asks you to submit

The documentation set is more standardised than the classification systems suggest. In practice a reviewer in any of these jurisdictions wants the same six things, and only the form numbers change.

  1. Welding procedure specification and its supporting procedure qualification record — ISO 15614-1 for European work, AWS D1.1 clause 4 for US work. A WPS without a matching PQR is a template, not a qualification.
  2. Welder qualification certificates — ISO 9606-1 or AWS D1.1 clause 4 part C, with the process, position and thickness range each welder is qualified for. A certificate naming only the process is insufficient.
  3. Consumable certificates and the storage record for low-hydrogen electrodes. Reviewers in humid climates ask for the drying log.
  4. NDT reports with the technician’s Level II certification, the procedure reference and the acceptance level applied.
  5. Dimensional and trial assembly report for any truss or frame that will not fit in a container without being split.
  6. Coating records — surface preparation grade, dry film thickness readings by member, and the batch certificates for the paint system.

Structural bolting systems

System Standard Grades What the inspector checks
US high-strength bolts ASTM F3125/F3125M Gr. A325, Gr. A490, Gr. F1852 twist-off RCSC Specification (2020): snug-tight, pretensioned or slip-critical; turn-of-nut or direct tension indicator
European preloaded bolts EN 14399-3 (HR) and EN 14399-4 (HV) 8.8 and 10.9 EN 1090-2 clause 8: tightening method, k-class, calibrated wrench or torque wrench with daily verification
European non-preloaded bolts EN 15048-1 8.8, 10.9 Bearing connections only; not permitted where the design assumes preload
Chinese high-strength bolts GB/T 1228 to GB/T 1231 8.8S and 10.9S Torque coefficient test per batch; GB 50205-2020 for the site inspection record
Australian high-strength bolts AS/NZS 1252.1 8.8, 10.9 Property class marking plus assembly verification testing

Four bolting traps in cross-code procurement

F3125 is not a new bolt. ASTM consolidated A325 and A490 into F3125 in 2016. A specification that still calls for A325 is satisfied by F3125 Gr. A325, but a submittal that lists only “A325” with no standard reference will be returned by a careful reviewer. Write both.

Thread form cannot be mixed. Unified inch threads and metric coarse threads are not interchangeable, and a galvanized assembly adds a further clearance allowance. If a US-designed frame is fabricated in China, the bolt hole diameters, the bolt lengths and the spanner sizes all change. Fix the thread standard in the order documents.

Galvanizing and slip-critical joints conflict. Hot-dip galvanized faying surfaces default to a lower slip factor unless the fabricator either roughens them or supplies tested class B surfaces. Painting the faying surface is generally prohibited. Confirm the slip factor in the design before the galvanizer loads the kettle.

Torque is not a universal number. A tightening torque derived from a k-factor of 0.13 will over-tension a batch with a tested coefficient of 0.11. Chinese 10.9S bolts ship with a batch torque coefficient certificate, and the site torque must be recalculated from it rather than copied from a table.

Corrosion protection and galvanizing

Reference Defines Values worth memorising
ISO 12944-2:2017 Atmospheric corrosivity categories and durability bands C1 to C5, plus CX for offshore; durability low, medium, high and very high
ISO 1461 Hot-dip galvanized coating on fabricated steel Minimum total coating mass 610 g/m² (about 85 µm) on steel 6 mm and thicker; lower masses permitted on thinner sections
ASTM A123/A123M Zinc coating on iron and steel products 2.0 oz/ft² (610 g/m²) on steel 3/16 in (4.8 mm) and thicker
ASTM A653/A653M Zinc-coated sheet steel G90 equals 0.90 oz/ft² total, approximately Z275; G60 approximately Z180
ASTM A792/A792M Aluminium-zinc coated sheet AZ50 and AZ55, the usual substrate for 55% Al-Zn roof and wall panels

Three practical rules follow. First, specify the corrosivity category, not the coating thickness, then let the coating thickness follow from ISO 12944-5. Second, treat cut edges, weld spatter and site-drilled holes as coating defects that need a zinc-rich repair coat, because no shop system survives an untreated edge in a C4 environment. Third, for coastal and marine sites use a duplex system — galvanizing plus a topcoat — since the paint alone will not hold at C5-M and the galvanizing alone will not hold its appearance.

Coating thickness is specified, not assumed: the same galvanized frame can be held to 55 µm, 65 µm or 63 µm depending on whether the order cites ISO 1461, ASTM A123 or JIS H 8641. Our companion reference sets the five galvanizing standards side by side, converts coating mass to thickness, and works the service-life arithmetic for each ISO 12944 corrosivity category: galvanizing coating thickness by standard.

What an approval package should contain

Document Purpose Common omission
Design basis statement Names every code, edition, national annex, and the load cases used Edition year left out, so the reviewer assumes the current one
Member and connection calculations Demonstrates utilisation in the nominated code Connection design skipped on the assumption that the supplier’s standard detail governs
Material certificates Proves grade, heat number and impact toughness Stockholder certificate submitted instead of a mill 3.1 certificate
WPS and PQR set Proves the welding procedure is qualified PQR written for a different thickness range than the actual plates
Welder and NDT operator certificates Proves personnel qualification and scope Certificates valid but outside the position or thickness range used
Coating specification and DFT record Proves the system meets the corrosivity category Only the shop primer is recorded; the finish coat is applied on site with no record
Erection drawings and anchor bolt plan Coordinates the foundation interface Anchor rod projection given without tolerance, causing site collisions
Packing list by mark Allows site receipt checking against the erection sequence Marks not matched to erection drawings, so the site opens every bundle

Seven mistakes that get a PEB submittal rejected

  1. Porting a design across codes. A member checked to AISC 360 and re-issued under EN 1993 without a re-check is the single most common technical objection raised against imported packages.
  2. Sending a GB 50205 weld package to an AISC reviewer. The documentation is real, but the reviewer has no basis to accept Grade I as equivalent to fracture-critical inspection. Map the acceptance criteria explicitly.
  3. Listing A325 in a bill of materials. The current standard is ASTM F3125. Omitting it looks like an outdated supply chain.
  4. Preloaded joints on galvanized members with no slip factor. The design assumes class A and the surface delivers less, so the connection is under-designed before it is built.
  5. Quoting galvanizing in microns against a specification in ounces per square foot. Both are legitimate; mixing them across a submittal and a purchase order is how a batch gets rejected at the galvanizer.
  6. Designing purlins to AISI S100 but loading them with Eurocode snow drift. The member standard and the load standard must come from the same regime, or the drift case must be converted with a stated basis.
  7. No trial assembly for long-span trusses. A 40 m truss that was never trial-assembled will find its mismatch on site, in the air, on a crane clock.

Need a package that survives a foreign reviewer?

SynJect fabricates to the code your engineer of record nominates rather than to a single house standard. We routinely deliver to AISC 360, EN 1090-2 execution classes up to EXC3, GB 50205 and AS/NZS 5131 projects, with the WPS, PQR, welder certificates and mill certificates issued in the format the reviewer expects.

Two starting points: our fabrication capabilities and the certificate register. For a specific project, send the design basis and we will return a code-compliance note with the quotation.

Where to obtain the current text of each steel building design code

Working from a second-hand copy of a standard is how edition errors enter a project. These are the issuing bodies that publish and sell the documents in the table above, plus the two international bodies behind the welding and corrosion references.

Issuing body Covers Publisher
AISC and ASCE United States: AISC 360, AISC 303, ASCE 7 aisc.org
CSA Group Canada: CSA S16, CSA S136 csagroup.org
CEN European Union: EN 1993, EN 1991, EN 1090 cencenelec.eu
BSI United Kingdom: BS EN adoptions and UK National Annexes bsigroup.com
SAC and SAMR China: GB 50017, GB 50205, GB 50661 sac.gov.cn
Bureau of Indian Standards India: IS 800, IS 875, IS 801 bis.gov.in
Standards Australia Australia and New Zealand: AS 4100, AS/NZS 1170, AS/NZS 5131 standards.org.au
ABNT Brazil: NBR 8800, NBR 14762 abnt.org.br
ISO and ASTM Welding quality, galvanizing, corrosivity and bolt specifications iso.org, astm.org

Keeping this reference current

Three of the documents above move on fixed cycles worth diarising. ASCE 7 and the IBC publish on a three-year cycle, and the MBMA manual follows the IBC, so a US package specified in 2026 will be reviewed against ASCE 7-22 and IBC 2024 until the next editions land. Eurocode 3 is mid-transition to its second generation, which means a project specified today may be checked against EN 1993-1-1 as amended by the second generation part if the National Annex has been updated. CSA S16 moved to the 2024 edition, superseding S16:19.

If you are specifying steel building design codes across more than one market, the practical rule is to write the edition year into the design basis statement and into the purchase order. A clause that says “AISC 360” invites a reviewer to assume the newest edition; a clause that says “AISC 360-22” does not. The same discipline applies to the material and execution standards that hang off the design code, which is why the reference above lists them together rather than as separate families.

Sources and scope

Compiled by the SynJect engineering team from publisher catalogues and standards bodies: AISC, ASCE, ICC, CSA Group, CEN, BSI, SAC, Standards Australia, ABNT, BSN, NSCP, the Saudi Building Code National Committee, SABS, ISO, ASTM and MBMA. This steel building design codes reference covers building structures only; it excludes bridges, cranes, offshore structures, pressure vessels and storage tanks, each of which has its own governing standard. Nothing here replaces the engineer of record’s judgement or the authority having jurisdiction’s written direction.