Home / Solutions / Steel Warehouse / Automated Storage Warehouse
Warehouse Automation Solutions
Maximize your vertical storage capacity and accelerate logistics flow with our precision-engineered Automated Storage and Retrieval System(ASRS) steel buildings. From ultra-tight CNC fabrication tolerances to heavy-duty floor load integrations, we deliver both rack-supported (rack-clad) and free-standing structural solutions. Our buildings are strictly designed to eliminate structural sway and ensure the flawless, continuous operation of your high-speed robotic stacker cranes.
Industry Pain Points & Solutions
The performance of an automated storage depends on much more than building height. We coordinate the building structure with storage loads, racking, stacker cranes, and material flow from the design stage to reduce installation conflicts and support reliable automated operation.
In an automated warehouse, the building is not just a shelter; it is the absolute foundation of your robotic systems. We engineer structural steel solutions designed specifically to eliminate the microscopic deflections, thermal movements, and installation bottlenecks that can paralyze a multi-million-dollar ASRS investment.
We engineer intelligent thermal expansion joints into the structural grid and utilize slotted bolt connections for secondary framing. Combined with a high-performance continuous insulation envelope, we stabilize the internal climate and completely decouple thermal movement from the crane's operating rails.
Rack loads, stacker-crane self-weight, operating and braking forces, and conveyor loads can all affect the structural system. If these loads are introduced after structural design is completed, reinforcement or redesign may be required.
We collect racking and automation equipment data during the design stage and incorporate relevant static and dynamic loads into structural calculations while providing suitable equipment connection and suspension provisions.
Traditional warehouses can tolerate slight ground settlement. But in an ASRS, a mere 5mm differential settlement at the column base translates to a 50mm tilt at the top of a 30m rack. The robotic cranes lose their coordinate targets, resulting in dropped pallets and massive system errors.
We co-engineer the anchor system with your civil contractor, utilizing ultra-thick, CNC-machined base plates with precision leveling nuts and non-shrink grouting space. Our rigid portal frame design redistributes stress, absorbing micro-settlements before they affect the verticality of the racks.
Massive exhaust fans and HVAC chillers placed on the roof generate continuous micro-vibrations. In a Rack-Supported Building (RSB), these vibrations travel directly down the structural columns to the crane's upper guide rails, causing premature wheel wear and disrupting sensitive WMS sensors.
We decouple dynamic loads. Our engineering team designs isolated, reinforced roof trusses specifically for mechanical equipment, utilizing heavy-duty vibration dampening mounts. This ensures that zero mechanical frequency is transferred to the delicate automation envelope below.
In Rack-Supported Buildings, the steel racking is erected before the roof and walls. A sudden rainstorm or prolonged UV exposure can rust the galvanized racks, coat the precision crane rails in mud, and destroy pre-wired electrical sensors before the building is even sealed.
We implement a modular "Follow-Up" envelope sealing strategy. Our pre-engineered roof and wall cladding systems are designed to be installed concurrently with the rack erection, layer by layer. This reduces the weather exposure window from months down to a few days, protecting your automation assets.
Technical Specifications
Technical specifications for an automated high-bay warehouse must address the building structure, racking system, and automation equipment as an integrated system. Rack loads, stacker-crane dynamic loads, structural deflection, column verticality, and floor tolerances are particularly important because they directly affect rack installation and automated operation.
| Parameter Category | Reference Range | Typical Reference Value |
|---|---|---|
| Customization | Available | |
| Warehouse Building Height | 12–40 m | 24 m |
| Building Span | 18–40 m | 24 m |
| Column Spacing | 6–12 m | 8 m |
| Racking Height | 10–35 m | 24 m |
| Racking Levels | 6–30+ levels | 12–20 levels |
| Unit Pallet Load | 500–1,500 kg/pallet | 1,000 kg/pallet |
| Load per Storage Location | 500–1,500 kg/location | 1,000 kg/location |
| Racking Load | Calculated based on storage locations, levels and unit loads | Project-specific |
| Stacker Crane Capacit | 500–1,500 kg | 1000 kg |
| Stacker Crane Operating Heigh | 10–35 m | 24 m |
| Stacker Crane Travel Speed | 80–200 m/min | 120 m/min |
| Stacker Crane Lifting Speed | 20–60 m/min | 40 m/min |
| Structural Steel Grade | S355 / ASTM A572 Gr.50 etc. | S355 |
| Floor Flatness | ±3–5 mm / 2 m | ±3 mm / 2 m |
| Structural Verticality | According to design codes and equipment requirements | Project-specific |
| Corrosion Protection Category | C1–C5 | C3 |
| Design Standards | EN / AISC / GB / AS / Local Codes | Project-specific |
NoteRacking, mezzanine and automation loads shall be confirmed against the final storage layout and vendor specifications before fabrication.
From Structural Planning to Automated Warehouse Delivery
Construction quality in an automated high-bay warehouse affects not only the building itself but also racking installation and automated equipment operation. Structural accuracy and system interfaces are controlled throughout planning, erection, and completion.
Engineering & Millimeter Detailing
We build a 3D digital twin of your structure in Tekla, importing your automation supplier's equipment models to verify every clearance before a single piece of steel is cut.
- Storage Capacity Planning
- Equipment Load Coordination
- BIM Clash Coordination
Steel Structure & High-Bay System Installation
Pre-marked, precision-machined steel members arrive at your site in optimal sequence for fast, weld-free assembly.
- Factory Fabrication
- Structural Accuracy
- Equipment Interfaces
Handoff & Equipment Integration
A rigid, weather-tight, and structurally verified building envelope is handed over, ready for immediate high-bay racking and robotic crane installation.
- Verified Rigidity: Fully tested for deflection limits, ready for instant crane rail mounting.
- Weather-Tight Seal: Premium roof and wall panels protect sensitive electronic automation assets.
- Lifecycle Documentation: Comprehensive handover of all warranties, MTCs (Mill Test Certificates), and as-built drawings.
Qualification Certificate
Your projects are protected by world-class standards. From CE (EN 1090) to ISO 9001, our qualifications are not just paper—they are the rigorous daily reality on our shop floor.




Recommended Product Systems
SynJect manufactures precision-engineered Portal Frames designed to maximize column-free interior space while minimizing material and shipping costs. Operating an 80,000 m² facility, we deliver robust structural frameworks tailored for global logistics parks and heavy manufacturing plants.
SynJect Steel Truss systems deliver unparalleled heavy load-bearing capacity and clear-span flexibility.
SynJect Envelope & Cladding Systems seal your structures with superior thermal performance and weatherproofing.
Related Projects
Frequently Asked Questions
What loads does the steel structure of an automated high-bay warehouse need to support?
The structure must consider not only self-weight, roof, wind, snow, and seismic loads, but also static and dynamic loads from racking, stacker cranes, conveyors, and other automation equipment. Final load combinations are determined through structural calculations based on local codes and equipment supplier data.
Can you design the structure around our warehouse layout?
Yes. Warehouse layouts, racking plans, equipment layouts and basic project data can be used as engineering inputs to establish the structural grid, spans, clear heights and equipment interfaces.
Can you design according to AISC or EN standards?
Yes. Depending on the project location, owner's requirements and contractual design basis, the applicable international or local code system can be adopted, including AISC, EN or the relevant national codes.
Can future expansion be considered in the initial structuraldesign?
Yes. Providing the expected expansion direction, future capacity and equipment upgrade plans at an early stage allows potential expansion interfaces, structural connections and loading conditions to be evaluated.
Can you provide a preliminary quotation with only a building layout?
A preliminary assessment is possible, but an accurate quotation normally requires building dimensions, design codes, loading conditions, envelope requirements, equipment information, project location and scope of supply. More complete information leads to a more accurate commercial scope.
We are building a H/600 AS/RS High-Bay Warehouse. At this height, will the building sway in strong winds and jam the stacker cranes?
This is the most fatal risk for AS/RS, but we have perfectly solved it. We abandon the loose drift standards of standard plants, utilizing high-rigidity lattice columns densely packed with cross bracing. We strictly control lateral drift to L/400 or tighter. This means even in howling winds and snow, the steel structure is locked into a "rigid body," ensuring stacker crane tracks never misalign or jam.
Fulfillment center fire requirements are extremely strict. Can your design pass FM Global or local fire audits?
Absolutely. Our engineers are well-versed in NFPA codes and FM Global audit requirements. In early design, we use BIM to reserve precise suspension points and massive loads for the giant ESFR (Early Suppression Fast Response) sprinkler systems and smoke vents. We apply sufficient fire-retardant coatings per local codes, ensuring your massive assets smoothly secure their operating permit.
Our racking layout is already finished. Can your columns be adjusted to avoid our racks?
They must be; this is "process reverse-engineering the building." Simply send us your 3D racking drawings, and our structural engineers will adjust the grid span in Tekla software, precisely "hiding" unavoidable internal columns within back-to-back rack gaps or main aisle intersections. We will never let a single column waste a pallet position.
We want to install Solar PV panels on the massive warehouse roof to save power. Can the steel frame support it?
Yes. Massive logistics roofs are perfect for PV generation. As long as you inform us during the design phase, we will preemptively add the weight of PV modules to the roof's additional dead load (usually adding 0.15 – 0.25 kN/m²). Meanwhile, our standing seam roofs use dedicated non-penetrating aluminum clamps that grip the PV rails directly—no drilling, zero leak risk.
We are building an overseas fulfillment center in LATAM/Middle East with a very tight schedule. Can you ship and install it in time?
Rapid overseas delivery is our forte. All components are 100% prefabricated, marked with 3D codes before leaving the factory, and shipped via high-density packing. Once on-site, because there is zero on-site welding, local workers simply tighten high-strength bolts with wrenches according to the manual—as fast as LEGOs. We compress lengthy, uncontrollable traditional overseas schedules by half, helping you open early.
Get Your 24-Hour BOQ and Cost Plan
See how much steel tonnage and ocean freight you can save before fabrication begins
Steel Weight Savings
1:1 Tekla 3D modeling optimizes beam-column ratios to eliminate redundant material costs.
Zero-Clash Code Verification
Checked against EN 1090 and local wind/seismic loads.
Engineer-to-Engineer Review
Verified by our lead engineers—Zero pushy sales calls, Just actionable data and factory price.
CE EN 1090-1•ISO 9001•ISO 14001•ISO 45001
Lead Engineers Online
🔒 100% Private and Secure, No Spam