Closed Environmentally Controlled Poultry House

Engineered Biosecurity

Modern high-density poultry production leaves no margin for structural or thermal failure. Backed by an 80,000 m² fabrication facility and 500,000-ton annual capacity, we manufacture precision-sealed PEB broiler and multi-tier layer houses engineered to hold 50 Pa negative pressure, resist severe ammonia corrosion, and safely carry automated feeding and climate systems.

Why Traditional Materials Fail in Modern Poultry Farming

In tunnel-ventilated poultry houses the structure directly dictates feed conversion ratio, flock mortality and HVAC electricity consumption. Replacing masonry, timber and angle-iron trusses with a solid-web PEB steel system removes four operational hazards.

Cross-section diagram of a closed poultry house showing laminar airflow entering through sidewall inlets, passing tiered cage equipment under negative pressure and exiting through end-wall exhaust fans
O DESAFIO

Masonry cracks and timber warps under humidity, so static pressure drops below 15 Pa. The result is dead air zones, heat-stress mortality and a 30% spike in exhaust fan electricity bills.

SOLUÇÃO DE ENGENHARIA SynJect

Millimetre-sealed envelope: ±1.0 mm CNC framing with tongue-and-groove PIR/PU sandwich panels and butyl-sealed joints holds 35–50 Pa negative static pressure, giving uniform wind-chill velocity across the whole flock.

Poultry house interior with flush white wall panels, smooth under-purlin ceiling and evaporative cooling pads along the sidewalls
O DESAFIO

Porous timber and exposed truss chords trap infective dust, feathers, Salmonella, avian influenza and darkling beetles. Exposed insulation is destroyed by rodents and high-pressure washdown.

SOLUÇÃO DE ENGENHARIA SynJect

Zero-harbourage smooth interior: solid-web tapered H-beams with a flush under-purlin ceiling or double-sided FRP/Plastisol lining, able to take 150-bar hot-water and acid/alkali disinfection with no pathogen retention between flocks.

Close-up of a hot-dip galvanized steel connection showing zinc spangle texture, stainless bolts and bonded sealing washers
O DESAFIO

Litter emits concentrated ammonia above 20 ppm plus hydrogen sulphide, and evaporative cooling pushes relative humidity past 80%. Painted steel trusses rust through at the welds within three to five years.

SOLUÇÃO DE ENGENHARIA SynJect

C5-A agricultural corrosion matrix: primary frames shot-blasted to ISO 8501-1 Sa 2.5 and hot-dip galvanized to ASTM A123 (≥ 85 μm / 600 g/m²). Secondary purlins use self-healing ZAM ZM275 steel with SS304 or Dacromet fasteners.

steel building for Poultry house
O DESAFIO

Interior columns obstruct pan feeders and skid-steer cleanout, and uncalculated trusses deflect or collapse when jammed auger lines load the roof.

SOLUÇÃO DE ENGENHARIA SynJect

12–32 m column-free spans with 0.25–0.60 kN/m² of equipment collateral load built into the Tekla LOD 400 calculation, including pre-punched bottom-flange suspension tabs for feeding and climate equipment.

O DESAFIO
SOLUÇÃO DE ENGENHARIA SynJect

Technical Specification Matrix

Every structure is calculated to local wind, snow and seismic codes (ASCE 7 / ASABE EP288 / Eurocode 3) and manufactured under CE EN 1090-1 EXC3 quality management.

Engineering parameter Floor-rearing broiler / breeder house Multi-tier caged layer / pullet house
Clear span width (column-free) 12.0 – 20.0 m (40–65 ft) 15.0 – 32.0 m (50–105 ft), 4–8 rows of H-cages
Eave height 2.6 – 3.5 m (high tunnel air velocity) 5.0 – 10.5 m (4–12 cage tiers plus manure pit)
Building length 80 – 150 m (matched to static pressure drop) 90 – 160 m (expansion joints over 120 m)
Roof pitch 1:10 – 1:12 (8–10%), flush interior ceiling 1:10 – 1:8 (10–12.5%)
Design collateral load (roof) 0.25 – 0.35 kN/m² (feeders, drinkers, brooders, inlets) 0.35 – 0.60 kN/m² (ceiling inlets, lighting, catwalk)
Negative pressure resistance Continuous 50 – 60 Pa inward suction Continuous 50 – 60 Pa inward suction
Primary steel grade & coating Q355B/D tapered H-beam, HDG ≥ 85 μm (ASTM A123) Q355B/D heavy H-beam, HDG ≥ 85 μm or C5 epoxy system
Secondary purlins / girts S350GD cold-formed ZAM (ZM275) S350GD cold-formed ZAM (ZM275)
Roof & wall insulation 75 – 120 mm PIR/PU sandwich panel (R ≥ 3.5–5.0) 75 – 150 mm PIR/PU or high-density rockwool
Pre-framed equipment openings Gable 50″/54″ cone fans, tunnel doors, sidewall cooling pads Multi-level exhaust fan banks, cooling rooms, egg conveyor tunnels

NoteVentilation, feeding and climate equipment layouts shall be coordinated with the integrator prior to fabrication.

Como seu projeto é construído

Agricultural projects often mean ten to fifty identical houses in a remote region. The three stages below exist to protect capex and schedule at that scale.

PHASE 01 / LOGISTICS

3D Container Nesting & Packing

Rafters are segmented and ZAM purlins and PIR panels are nested using 3D volumetric simulation, lifting 40HQ loading efficiency from around 60% to over 85% and cutting ocean freight per bird housed.

PHASE 02 / ERECTION

Pre-Punched, Zero-Welding Assembly

Every H-beam, wind column and fan-framing channel is CNC-drilled and hard-stamped with Tekla part numbers. Local crews bolt the structure together with HSFG bolts, cutting commissioning time by up to 40%.

PHASE 03 / HANDOVER

Pressure Test & Documentation

Before handover the envelope is checked for airtightness against the design negative pressure, and the structural file is issued for the integrator and the local authority.

Certificado de Qualificação

Seus projetos são protegidos por normas de nível internacional. Da certificação CE (EN 1090) à ISO 9001, nossas certificações não são apenas papel — elas são a realidade rigorosa do nosso dia a dia na fábrica.

AISCCEOTCSoldador Internacional
Sistema de Gestão da Qualidade ISO 9001

Sistemas de produtos recomendados

Frames, purlins and envelope systems for poultry houses, from one fabrication source.

Interior de um armazém com estrutura de portal de aço de vários vãos, com colunas azuis, corredores de estantes para paletes, empilhadeiras e contraventamento transversal no telhado

A SynJect fabrica estruturas em portal projetadas com precisão, destinadas a maximizar o espaço interno sem colunas e, ao mesmo tempo, minimizar os custos com materiais e transporte. Com uma unidade de 80.000 m², fornecemos estruturas robustas sob medida para parques logísticos globais e fábricas de manufatura pesada.

Perguntas frequentes

How do you prevent roof collapse when automated feed augers jam or overload?

Generic warehouse suppliers calculate only dead and live roof loads. We engineer a dedicated 0.25 to 0.60 kN/m² collateral load into the primary rigid frames and purlins, with deflection limits of L/240 to L/360, so the roof never sags or breaks the seal at sidewall ventilation inlets.

For tunnel-ventilated houses with evaporative cooling pads and high litter humidity, we recommend full hot-dip galvanizing (≥ 85 μm) for primary frames and ZAM ZM275 for secondary purlins. Zinc bonds metallurgically to the steel, giving 25–30+ years of maintenance-free protection, whereas paint blisters and rusts at connection joints within a few years.

Yes. Share the equipment layout from your integrator and our Tekla LOD 400 detailers model every exhaust fan bank, evaporative cooling pad opening, tunnel door and sidewall inlet into the secondary framing. All sub-frames arrive pre-cut and ready to bolt.

Obtenha o seu BOQ e plano de custos em 24 horas

Veja quanto pode poupar em tonelagem de aço e frete marítimo antes do início da fabricação

8–15%

Redução do peso do aço

A modelação 3D 1:1 no Tekla otimiza as relações viga-coluna para eliminar custos com material redundante.

0,0 mm

Verificação de código sem conflitos

Verificado em conformidade com a norma EN 1090 e com as cargas eólicas e sísmicas locais.

100%

Revisão de Engenheiro para Engenheiro

Verificado pelos nossos engenheiros principais — Sem chamadas de vendas insistentes, apenas dados úteis e preço de fábrica.

CE EN 1090-1•ISO 9001•ISO 14001•ISO 45001

Balcão de Engenharia e Informações

Engenheiros-chefe online

Desenhos
Desenhos

🔒 100% privado e seguro, sem spam