Closed Environmentally Controlled Poultry House

Engineered Biosecurity

Modern high-density poultry production leaves no margin for structural or thermal failure. Backed by an 80,000 m² fabrication facility and 500,000-ton annual capacity, we manufacture precision-sealed PEB broiler and multi-tier layer houses engineered to hold 50 Pa negative pressure, resist severe ammonia corrosion, and safely carry automated feeding and climate systems.

Why Traditional Materials Fail in Modern Poultry Farming

In tunnel-ventilated poultry houses the structure directly dictates feed conversion ratio, flock mortality and HVAC electricity consumption. Replacing masonry, timber and angle-iron trusses with a solid-web PEB steel system removes four operational hazards.

Cross-section diagram of a closed poultry house showing laminar airflow entering through sidewall inlets, passing tiered cage equipment under negative pressure and exiting through end-wall exhaust fans
LE DÉFI

Masonry cracks and timber warps under humidity, so static pressure drops below 15 Pa. The result is dead air zones, heat-stress mortality and a 30% spike in exhaust fan electricity bills.

SOLUTION TECHNIQUE SynJect

Millimetre-sealed envelope: ±1.0 mm CNC framing with tongue-and-groove PIR/PU sandwich panels and butyl-sealed joints holds 35–50 Pa negative static pressure, giving uniform wind-chill velocity across the whole flock.

Poultry house interior with flush white wall panels, smooth under-purlin ceiling and evaporative cooling pads along the sidewalls
LE DÉFI

Porous timber and exposed truss chords trap infective dust, feathers, Salmonella, avian influenza and darkling beetles. Exposed insulation is destroyed by rodents and high-pressure washdown.

SOLUTION TECHNIQUE SynJect

Zero-harbourage smooth interior: solid-web tapered H-beams with a flush under-purlin ceiling or double-sided FRP/Plastisol lining, able to take 150-bar hot-water and acid/alkali disinfection with no pathogen retention between flocks.

Close-up of a hot-dip galvanized steel connection showing zinc spangle texture, stainless bolts and bonded sealing washers
LE DÉFI

Litter emits concentrated ammonia above 20 ppm plus hydrogen sulphide, and evaporative cooling pushes relative humidity past 80%. Painted steel trusses rust through at the welds within three to five years.

SOLUTION TECHNIQUE SynJect

C5-A agricultural corrosion matrix: primary frames shot-blasted to ISO 8501-1 Sa 2.5 and hot-dip galvanized to ASTM A123 (≥ 85 μm / 600 g/m²). Secondary purlins use self-healing ZAM ZM275 steel with SS304 or Dacromet fasteners.

steel building for Poultry house
LE DÉFI

Interior columns obstruct pan feeders and skid-steer cleanout, and uncalculated trusses deflect or collapse when jammed auger lines load the roof.

SOLUTION TECHNIQUE SynJect

12–32 m column-free spans with 0.25–0.60 kN/m² of equipment collateral load built into the Tekla LOD 400 calculation, including pre-punched bottom-flange suspension tabs for feeding and climate equipment.

LE DÉFI
SOLUTION TECHNIQUE SynJect

Technical Specification Matrix

Every structure is calculated to local wind, snow and seismic codes (ASCE 7 / ASABE EP288 / Eurocode 3) and manufactured under CE EN 1090-1 EXC3 quality management.

Engineering parameter Floor-rearing broiler / breeder house Multi-tier caged layer / pullet house
Clear span width (column-free) 12.0 – 20.0 m (40–65 ft) 15.0 – 32.0 m (50–105 ft), 4–8 rows of H-cages
Eave height 2.6 – 3.5 m (high tunnel air velocity) 5.0 – 10.5 m (4–12 cage tiers plus manure pit)
Building length 80 – 150 m (matched to static pressure drop) 90 – 160 m (expansion joints over 120 m)
Roof pitch 1:10 – 1:12 (8–10%), flush interior ceiling 1:10 – 1:8 (10–12.5%)
Design collateral load (roof) 0.25 – 0.35 kN/m² (feeders, drinkers, brooders, inlets) 0.35 – 0.60 kN/m² (ceiling inlets, lighting, catwalk)
Negative pressure resistance Continuous 50 – 60 Pa inward suction Continuous 50 – 60 Pa inward suction
Primary steel grade & coating Q355B/D tapered H-beam, HDG ≥ 85 μm (ASTM A123) Q355B/D heavy H-beam, HDG ≥ 85 μm or C5 epoxy system
Secondary purlins / girts S350GD cold-formed ZAM (ZM275) S350GD cold-formed ZAM (ZM275)
Roof & wall insulation 75 – 120 mm PIR/PU sandwich panel (R ≥ 3.5–5.0) 75 – 150 mm PIR/PU or high-density rockwool
Pre-framed equipment openings Gable 50″/54″ cone fans, tunnel doors, sidewall cooling pads Multi-level exhaust fan banks, cooling rooms, egg conveyor tunnels

NoteVentilation, feeding and climate equipment layouts shall be coordinated with the integrator prior to fabrication.

Comment votre projet est construit

Agricultural projects often mean ten to fifty identical houses in a remote region. The three stages below exist to protect capex and schedule at that scale.

PHASE 01 / LOGISTICS

3D Container Nesting & Packing

Rafters are segmented and ZAM purlins and PIR panels are nested using 3D volumetric simulation, lifting 40HQ loading efficiency from around 60% to over 85% and cutting ocean freight per bird housed.

PHASE 02 / ERECTION

Pre-Punched, Zero-Welding Assembly

Every H-beam, wind column and fan-framing channel is CNC-drilled and hard-stamped with Tekla part numbers. Local crews bolt the structure together with HSFG bolts, cutting commissioning time by up to 40%.

PHASE 03 / HANDOVER

Pressure Test & Documentation

Before handover the envelope is checked for airtightness against the design negative pressure, and the structural file is issued for the integrator and the local authority.

Certificat de qualification

Vos projets bénéficient d'une protection conforme aux normes internationales les plus strictes. De la norme CE (EN 1090) à la norme ISO 9001, nos certifications ne sont pas que des simples certificats sur papier : elles reflètent la rigueur qui caractérise notre travail au quotidien dans nos ateliers.

AISCCEOTCSoudeur international
Système de gestion de la qualité ISO 9001

Systèmes de produits recommandés

Frames, purlins and envelope systems for poultry houses, from one fabrication source.

Intérieur d'un entrepôt doté d'une charpente en acier à portiques à plusieurs travées, avec des poteaux bleus, des allées de rayonnages à palettes, des chariots élévateurs et des contreventements transversaux au niveau de la toiture

SynJect fabrique des charpentes en portique de haute précision, conçues pour optimiser l'espace intérieur sans poteaux tout en réduisant au minimum les coûts de matériaux et de transport. Grâce à notre site de 80 000 m², nous fournissons des structures robustes sur mesure destinées aux parcs logistiques internationaux et aux usines de fabrication de produits lourds.

Questions fréquentes

How do you prevent roof collapse when automated feed augers jam or overload?

Generic warehouse suppliers calculate only dead and live roof loads. We engineer a dedicated 0.25 to 0.60 kN/m² collateral load into the primary rigid frames and purlins, with deflection limits of L/240 to L/360, so the roof never sags or breaks the seal at sidewall ventilation inlets.

For tunnel-ventilated houses with evaporative cooling pads and high litter humidity, we recommend full hot-dip galvanizing (≥ 85 μm) for primary frames and ZAM ZM275 for secondary purlins. Zinc bonds metallurgically to the steel, giving 25–30+ years of maintenance-free protection, whereas paint blisters and rusts at connection joints within a few years.

Yes. Share the equipment layout from your integrator and our Tekla LOD 400 detailers model every exhaust fan bank, evaporative cooling pad opening, tunnel door and sidewall inlet into the secondary framing. All sub-frames arrive pre-cut and ready to bolt.

Obtenez votre devis et votre plan de coûts en 24 heures

Découvrez combien vous pouvez économiser en tonnage d'acier et en frais de transport maritime avant le début de la fabrication

8–15%

Réduction du poids de l'acier

La modélisation 3D 1:1 dans Tekla optimise les rapports poutre-poteau afin d'éliminer les coûts liés aux matériaux superflus.

0,0 mm

Vérification de code sans conflit

Vérifié conformément à la norme EN 1090 et aux charges locales dues au vent et aux séismes.

100%

Revue d'ingénieur à ingénieur

Vérifié par nos ingénieurs en chef — Aucun appel commercial insistant, uniquement des données exploitables et des prix d'usine.

CE EN 1090-1•ISO 9001•ISO 14001•ISO 45001

Guichet « Ingénierie et recherche »

Ingénieurs en chef en ligne

Dessins
Dessins

🔒 100 % confidentiel et sécurisé, sans spam