Purlins are secondary load-bearing members in the roof system that support roof panels. Arranged perpendicular to roof beams, they transfer dead loads, live loads, and wind loads from the roof panels to the roof beams or rigid frame rafters. Common forms include C-section, Z-section, H-beam, and square tube purlins. Among them, C and Z cold-formed thin-walled purlins are most widely used in portal frame lightweight buildings due to their light weight and easy installation. Z-section purlins can be overlapped to form continuous spans, resulting in smaller mid-span bending moments; C-section purlins are simple to manufacture and connect. Sag rods and struts are usually installed between purlins to reduce the out-of-plane effective length of the roof.

Technical Specifications

Parameter Specification
Common Sections C-section, Z-section, square tube, H-beam
Section Height C120~C350, Z120~Z350
Wall Thickness Range mm ~ 3.5mm
Material Q235B/Q355B (Galvanized layer ≥180g/m²)
Spacing m ~ 1.5m (determined by panel type and load)
Span Simply supported 6m~9m, continuous Z-sections can be larger
Connection Method Self-tapping screws to roof panels, bolts to rigid frame rafters
Accessories Sag rod, steel purlin spacer tube, strut, flange brace
Anti-corrosion Treatment Galvanized (default), or painted after strip steel forming
Execution Standard GB 51022, GB/T 6725

Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Light weight, steel saving: Cold-formed thin-walled purlins save 30%~50% steel compared to H-beam purlins. Corrosion damage on thin-walled members needs attention: Galvanized layer scratches during transport/installation must be touched up, otherwise rust easily occurs.
Convenient installation: C/Z purlin lengths can be customized, bolted on-site, ensuring fast construction. Requires sag rods for torsion: Purlins easily suffer from flexural-torsional buckling down the roof slope; sag rods must be set as designed.
Z-sections can continuously overlap: Reduces mid-span bending moments, allowing for smaller purlin cross-sections. Reverse bending for purlins in wind uplift zones: Roof corners have high wind suction; purlin design must account for reverse bending conditions.
Mature accessory system: Sag rods, steel purlin spacer tube, and flange braces are standardized, offering good overall economy. Self-tapping screw leakage risk: Connections between panels and purlins require waterproof washers and standard drilling.
Galvanized anti-corrosion: Anti-corrosion is completed ex-factory, no on-site painting needed, low maintenance cost. Wall thickness limit: Thickness exceeding 3.5mm usually switches to H-beams or square tubes to meet bearing capacity.

Frequently Asked Questions

What are the types of purlins?

C-section, Z-section, square tube, H-beam purlins. C/Z types are common for light plants.

Z purlins can continuously overlap and save steel; C purlins are simple to make and install, often used for smaller spans.

Commonly 0.5~1.5m, determined by roof panel stiffness and load calculations.

To reduce the out-of-plane effective length of purlins and prevent flexural-torsional buckling.

Q235B/Q355B hot-dip galvanized strip steel, usually with galvanizing amount ≥180g/m².

Fixed to purlins by self-tapping screws (with waterproof washers) penetrating the panels, or using dedicated concealed brackets.

Connects purlins to the lower flange of the rigid frame rafter, preventing the lower flange from compressive buckling.

C-sections (simply supported) typically 6~8m; Z-sections (continuous overlapping) can reach 9m or more.

Generally no; scratched areas during transport/installation require anti-rust touch-up paint.

Purlins in edge/corner wind suction zones need reverse bending verification, and connection bolts/sag rods should be densified.

Sag Rod

Space Frame Sag Rod

Sag rods (Eave Strut Purlin) are slender round steel tension members installed in the roof and wall girt systems of lightweight steel structures. They connect adjacent purlins or wall girts to reduce the out-of-plane effective length of the members, preventing purlins (or girts) from lateral bending and torsional deformation under wind loads, dead weight, and roof loads. Sag rods typically use HPB300 round steel with common diameters of φ12 or φ14, connected to the purlin web via bending or threaded ends with bolts. Diagonal sag rods and struts are usually installed at the ridge of double-pitch roofs to form a stable geometric invariable triangular system.

Technical Specifications

Parameter Specification
Common Materials HPB300 round steel (Q235)
Diameter commonly φ12)
Layout Spacing Based on purlin span: 4~6m generally 1 row, 6~9m generally 2 rows, above 9m generally 3 rows.
Connection Method Threaded ends, bolted to purlin web
Accessories Diagonal sag rod, steel purlin spacer tube (tube)
Installation Position Near the upper flange or center of the purlin web
Tensioning Requirements Must be pulled straight and tensioned during installation; no slack allowed
Anti-corrosion Treatment Hot-dip galvanizing or anti-rust paint
Installation Tools Wrench, tensioner
Execution Standard GB 51022

Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Simple structure: Round steel sag rods are easy to source and low cost. Tension degree must be controlled: Too loose provides no support; too tight may deform the purlins.
Significantly improves purlin stability: Reduces the out-of-plane effective length of purlins, preventing flexural-torsional buckling. Rust risk: Slender round steel easily rusts; requires galvanizing or painting and maintenance.
Convenient installation: Threaded ends, on-site bolting, fast construction. Connection nodes prone to loosening: Nuts may loosen under long-term vibration; regular checks needed.
Adjustable: Sag rod tightness can be finely adjusted via nuts. Densification needed in high-wind areas: Steep slopes and large wind suction zones require denser sag rod spacing.
Mature accessory system: Forms a complete bracing system with steel purlin spacer tube, diagonal sag rods, and struts. Cannot bear compression: Sag rods can only bear tension; compression zones require steel purlin spacer tubes.

Frequently Asked Questions

What is the function of a sag rod?

Connects adjacent purlins, reduces purlin out-of-plane effective length, and prevents lateral buckling and torsion.

Commonly HPB300 round steel, diameter φ12~φ14.

Threaded ends pass through the purlin web and are tightened with double nuts.

Sag rods bear tension; struts (steel purlin spacer tube) bear both tension and compression, used at ridges and eaves.

Based on span: 4~6m usually 1 row, 6~9m usually 2 rows, >9m usually 3 rows.

Generally bolted; welding is not recommended to avoid damaging the galvanized layer and purlins.

Retighten the nuts, or replace if necessary.

Yes, wall girts (wall purlins) also need sag rods to ensure out-of-plane stability.

Set at both sides of the ridge and eaves, forming triangular stable units with struts.

Hot-dip galvanizing is preferred, or two coats of anti-rust paint + topcoat.

Steel Purlin Spacer Tube

Space Frame Purlin Spacer Tube

steel purlin spacer tube are short steel tubes placed over round steel sag rods in lightweight steel structures. Together with the sag rods, they form struts used in areas subjected to both tension and compression (such as roof ridges, eaves, and steep-sloped roofs). steel purlin spacer tube are generally made of Q235 welded steel pipes or galvanized steel pipes, with common diameters of φ32×2.0~2.5, and lengths equal to the purlin spacing. steel purlin spacer tube convert the sag rod system from a tension-only system into a two-force member capable of bearing compression, ensuring the geometric invariability of the roof.

Technical Specifications

Parameter Specification
Common Specifications φ32×2.0~2.5
Material Q235 welded steel pipe or galvanized steel pipe
Length Equal to purlin spacing (approx. 0.5~1.5m)
Installation Position Roof ridges, eaves, and sag rod locations requiring compression resistance
Relationship with Sag Rod Sleeved over the round steel sag rod, with both ends pressed tightly against the purlins
Connection Method Sag rod passes through the sleeve, locked by nuts at both ends
Anti-corrosion Treatment Hot-dip galvanizing or anti-rust paint
Function Enables the sag rod system to bear both tension and compression
Accessories Round steel sag rod, diagonal sag rod
Execution Standard GB 51022

Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Simple structure: Ordinary steel pipe slipped over the sag rod, low cost. Exact length required: Too long cannot fit tightly, too short leaves a gap; requires on-site measurement.
Enables sag rods to bear compression: Solves the issue of round steel sag rods not bearing compression, forming stable struts. Both ends must press tightly: After installation, both ends must tightly fit the purlin webs without gaps.
Convenient installation: Installed synchronously with sag rods, no extra welding needed. Rust risk: Thin pipe walls require galvanizing for anti-corrosion.
Standardized: Specifications match purlin spacing, easy selection. Gap with sag rod: The inner diameter of the sleeve should be 2~4mm larger than the sag rod for easy insertion.
Improves overall roof stiffness: Forms a geometric invariable system together with sag rods and diagonal sag rods. Cannot replace diagonal sag rods: Sleeve struts still need to cooperate with diagonal sag rods to form a complete system.

Frequently Asked Questions

What is a steel purlin spacer tube?

A short steel purlin spacer tube over a round steel sag rod, turning the sag rod system into a strut that can bear compression.

Commonly φ32×2.0~2.5 galvanized steel pipes.

The sag rod passes through the sleeve; the sleeve ends press tightly against purlin webs, and sag rod ends are locked with nuts.

Ridges, eaves, and other areas subjected to both tension and compression.

Equal to the purlin spacing, generally 0.5~1.5m.

No, ordinary round steel sag rods can only bear tension; compression zones must have sleeve struts.

Hot-dip galvanizing is preferred, or anti-rust paint.

No, the sag rod nuts lock tightly to make the sleeve press tight.

At the ridge, diagonal sag rods + sleeve struts form a triangular stable unit.

No, steel purlin spacer tube only serve as struts and do not bear roof loads.

Heavy-duty galvanised or stainless steel gutters supplied for a space frame structure

Space Frame Steel Gutters

Steel Gutters are metal trench components arranged at the edges of plant and building roofs to collect and discharge rainwater, usually set along the eaves or as internal valley Steel Gutters, connecting to downspouts via scuppers. By material, they can be divided into galvanized steel gutters, stainless steel gutters (201/304), and color-coated steel gutters; by layout, into external gutters (hung outside eaves) and internal gutters (embedded within the roof). Gutter design must consider catchment area, rainfall intensity, bottom slope, and scupper sizes to ensure no overflow, backflow, or leakage during rainstorms.

Technical Specifications

Parameter Specification
Common Materials Galvanized steel, Stainless steel 304/316, Color-coated steel sheet
Plate Thickness mm ~ 4.0mm
Section Forms Rectangular, trapezoidal, curved
Common Dimensions Width 300~1200mm, Depth 150~800mm
Slope Gutter bottom longitudinal slope ≥0.5% (sloping towards scupper)
Scupper Spacing m (calculated based on rainfall volume)
Connection Welded or seamed, overlap ≥100mm
Anti-corrosion Stainless steel needs no anti-corrosion; galvanized/color steel maintained per environment
Accessories Scuppers, downspouts, gutter brackets, end caps
Execution Standard GB 50015 "Standard for design of building water supply and drainage", GB 51022

Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.

Advantages vs Engineering Considerations

Advantages Engineering Considerations
Organized drainage: Prevents rainwater from randomly washing over walls and foundations. Welds prone to leakage: Poor on-site welding leads to leaks; requires full welding and water tightness tests.
Corrosion-resistant materials: Stainless steel gutters can be used in humid and corrosive environments. Cold regions need freeze protection: Internal gutters in cold areas require insulation to prevent freezing.
Factory prefabrication: Manufactured in segments, assembled on-site, fast construction. Blockage risks: Leaves and dust easily block scuppers; requires regular cleaning.
Neat appearance: Metal gutters coordinate aesthetically with building facades. Corrosive environments demand specific materials: Chemical/coastal areas must use 316 stainless steel or thickened galvanization.
Customizable: Cross-section dimensions and forms customized per architectural and drainage needs. Thermal expansion must be considered: Long gutters need expansion joints or sliding brackets.

Frequently Asked Questions

What materials are used for Steel Gutters?

Commonly galvanized steel sheet, stainless steel 304/316, color-coated steel sheet.

Generally 1.0~4.0mm; large-span Steel Gutters use thick plates or additional gutter brackets.

External Steel Gutters are hung outside eaves; internal Steel Gutters are embedded inside the roof, flanked by roof surfaces.

The longitudinal bottom slope is generally ≥0.5%, sloping towards the scupper.

Generally ≤30m or one per bay, calculated by local rainfall intensity and catchment area.

Water tightness tests are conducted after full welding, followed by exterior anti-corrosion or waterproof coatings.

Stainless steel is exempt; galvanized sheets get topcoats; chemical zones use 316 stainless steel.

Internal Steel Gutters need insulation to prevent frost heaving cracks and frozen scuppers.

Lengths exceeding 30m require expansion joints or one end with a sliding bracket.

Clean welds, re-weld, apply waterproof coating, or replace plate segments if necessary.

Qualification Certificate

Your projects are protected by world-class standards. From CE (EN 1090) to ISO 9001, our qualifications are not just paper—they are the rigorous daily reality on our shop floor.

AISCCEOTCInternational Welder
ISO 9001 Quality Management System

Have drawings or a BOQ ready?

SynJect
SynJect factory
SynJect factory
SynJect factory
Kunlun Lu
SynJect factory
SynJect factory
SynJect factory
SynJect factory
SynJect factory

SynJect:Scale. Precision. Certainty.

SYNJECT delivers comprehensive steel structure solutions engineered for the global value chain. From investors seeking ROI to engineers demanding exact compliance, we transform complex blueprints into robust realities—on time and without friction.

From Blueprint to Site. Zero Friction.

Detailed Engineering & Shop Drawing DevelopmentNesting & Material OptimizationRaw Material Incoming InspectionCNC Cutting & Edge PreparationWeld Distortion StraighteningNon-Destructive Testing (NDT)Trial Assembly & Shop AlignmentSurface Preparation & Protective CoatingMeasure Paint Film ThicknessFinal Quality Inspection & CertificationExport Packaging & Logistics ProtectionGlobal Field Erection & Site Management
Stage.01

Detailed Engineering

Utilizing advanced BIM platforms such as Tekla Structures, detailed 3D modeling and shop drawings are executed strictly in compliance with AISC 360 or Eurocode 3 (EN 1993). Connection designs are rigorously verified, with manufacturing drawings generated to ISO 2768-m tolerance standards. 100% clash detection with primary architectural and MEP systems is performed to ensure zero structural conflicts during field erection.

STANDARDAISC 360 / EN 1993
METRIC VALUETolerance ±0.01mm
Stage.02

Nesting & Material Optimization

Intelligent nesting layouts are performed using advanced software like FastCAM/SigmaNEST in accordance with EN 10029 / ASTM A6 dimensional standards. Accounting for cutting kerf (2mm–5mm depending on plate thickness) and thermal contraction allowances, raw material utilization exceeds 92%. Offcuts are digitally barcode-tracked to ensure 100% mill test report (MTR) traceability.

STANDARDEN 10029 / ASTM A6
METRIC VALUEUtilization 95%
Stage.03

Raw Material Incoming Inspection

All structural steel (Q355B/C/D, ASTM A572 Gr.50, S355JR/J2) must be accompanied by EN 10204 3.1 Mill Test Reports (MTR). Incoming quality control conducts 100% dimensional and visual inspections under ASTM A6 / EN 10029, verifying thickness tolerances (Class A/B) and internal lamination integrity via Ultrasonic Testing (UT) to ASTM A435. Chemical composition and mechanical properties are spot-verified by accredited 3rd-party labs.

STANDARDEN 10204 3.1 / ASTM A435
METRIC VALUEClass A/B and ASTM A435
Stage.04

CNC Cutting & Edge Preparation

Plate profiling and component cutting are executed via CNC oxy-fuel, high-definition plasma, and multi-kW fiber laser equipment. Cut surface quality strictly complies with EN ISO 9013 for perpendicularity and surface roughness ±2.5°, Range 3/4 tolerance. Multi-axis CNC beveling machines execute weld prep bevel angles within ±2.5° and root face dimensions within ±1.0 mm.

STANDARDEN ISO 9013
METRIC VALUERa ≤12.5μm
Stage.05

Weld Distortion Straightening

Welding is performed exclusively by AWS D1.1 or EN ISO 9606 certified welders using qualified Welding Procedure Specifications (WPS) supported by Procedure Qualification Records (PQR) per AWS D1.1 / ISO 15614. Submerged Arc Welding (SAW) and Flux-Cored Arc Welding (FCAW) dominate Complete Joint Penetration (CJP) and fillet welds. Heat input is strictly controlled, achieving weld quality levels conforming to ISO 5817 Quality Level B or AWS D1.1 standards.

STANDARDAWS D1.1 / EN ISO 9606
METRIC VALUEISO 5817Level B
Stage.06

Non-Destructive Testing (NDT)

Post-weld angular distortion, camber, and sweep are rectified using automated hydraulic flange straighteners and controlled thermal flame straightening. Heating temperatures for High-Strength Low-Alloy (HSLA) steels are strictly maintained between 600℃ - 650℃ (air-cooled, zero water quenching) to prevent microstructural degradation. Post-straightening straightness tolerances meet ±3 mm, conforming to EN 1090-2 Execution Class 2 (EXC2) and AISC COSP standards.

STANDARDEN 1090-2 EXC2 / AISC COSP
METRIC VALUETolerances ±3 mm
Stage.07

Trial Assembly & Shop Alignment

NDT protocols are operated by ISO 9712 / ASNT Level II certified NDT personnel. 100% of critical Complete Joint Penetration (CJP) welds undergo Ultrasonic Testing (UT per ISO 17640 / ASTM E164) or Magnetic Particle Testing (MT per ISO 17638 / ASTM E709). Radiographic Testing (RT) is applied as requested for heavy sections. Weld acceptance conforms strictly to ISO 11666 Acceptance Level 1 or AWS D1.1 criteria.

STANDARDISO 11666 Level 1 / AWS D1.1
METRIC VALUE100% UT
Stage.08

Surface Preparation & Protective Coating

Complex geometries, long-span trusses, and heavy framing undergo 1:1 physical trial assembly or high-precision 3D laser scanning virtual assembly per EN 1090-2 / AISC requirements. Bolt hole alignment is verified (≥ 95% free-pass rate for high-strength bolts), and critical dimensions (span, camber, 3D spatial alignment) are verified within tight tolerance limits (±2.0 mm) to eliminate site fitting risks.

STANDARDAISC / EN 1090-2
METRIC VALUETolerance ±2.0 mm
Stage.09

Measure Paint Film Thickness

Structural members undergo automated shot blasting to achieve SSPC-SP10 / NACE No. 2 / ISO 8501-1 Sa 2.5 cleanliness, with a surface profile (anchor depth) of 45–75μm. High-performance protective coatings are applied using airless spray technology in compliance with ISO 12944 (C3 to CX corrosive environments), featuring Inorganic/Organic Zinc-Rich Epoxy Primers, Epoxy Micaceous Iron Oxide Intermediate coats, and Polyurethane/Fluorocarbon Topcoats. Dry Film Thickness (DFT) is verified using calibrated magnetic gauges adhering strictly to the 90/10 rule.

STANDARDISO 8501-1 Sa 2.5 / ISO 12944
METRIC VALUE45 - 75μm
Stage.10

Final Quality Inspection & Certification

Final Quality Control (FQC) performs a comprehensive holistic audit, inspecting paint aesthetics (zero runs, pinholes, sagging), critical geometry, bolt hole pitches, and laser/stenciled component mark traceability. A complete Manufacturing Data Report (MDR)—comprising MTRs, NDT records, coating inspection logs, and Certificates of Conformance—is compiled to support CE Marking (DoP under EN 1090) and AISC final acceptance.

STANDARDEN 1090 / AISC
METRIC VALUEQA/QC Final Release
Stage.11

Export Packaging & Logistics Protection

Protective packaging is engineered for containerized (40HQ/OT/FR) and breakbulk ocean freight under heavy maritime transit conditions. Structural members are bundled on heavy-duty steel skids with high-tensile steel strapping. Machined connections and contact surfaces are wrapped with VCI anti-corrosion film, EPE foam padding, and heavy rubber cushions. All timber packing complies fully with ISPM 15 phytosanitary standards and IMO Cargo Stowage and Securing (CSS) rules.

STANDARDISPM 15 / IMO CSS
METRIC VALUE40HQ/OT/FR
Stage.12

Global Field Erection & Site Management

We deliver international site erection supervision and turnkey EPCM construction services adhering to OSHA 1926 safety protocols, AISC COSP, and EN 1090-2 erection standards. Field teams, led by multilingual HSE and QA/QC engineers, utilize high-precision total stations to maintain structural plumbness within H/1000 (≤25mm max). High-Strength Structural Bolting is executed via calibrated Wrench or Turn-of-Nut methods with 100% torque audit documentation.

STANDARDOSHA 1926 / EN 1090-2
METRIC VALUE≤ H/1000

Get Your 24-Hour BOQ and Cost Plan

See how much steel tonnage and ocean freight you can save before fabrication begins

8–15%

Steel Weight Savings

1:1 Tekla 3D modeling optimizes beam-column ratios to eliminate redundant material costs.

0.0mm

Zero-Clash Code Verification

Checked against EN 1090 and local wind/seismic loads.

100%

Engineer-to-Engineer Review

Verified by our lead engineers—Zero pushy sales calls, Just actionable data and factory price.

CE EN 1090-1•ISO 9001•ISO 14001•ISO 45001

Engineering & Inquiry Desk

Lead Engineers Online

Drawings
Drawings

🔒 100% Private and Secure, No Spam