Home / Products / Space Frame Structure / Primary Structural System
Primary Structural System
Space Frame Steel Columns
Steel columns are the main vertical load-bearing components in steel structure workshops, warehouses, super high-rise, and large-span buildings. They bear the axial force, bending moment, and shear force transmitted from steel beams, roof panels, floor slabs, and crane beams, reliably transferring the load to the foundation. By section form, they can be divided into H-beam columns, welded box (rectangular tube) columns, circular tube columns, cruciform columns, and latticed columns; by stress characteristics, they are divided into axially loaded columns, frame columns, and bent columns. Prefabricated in the factory and assembled on-site via bolts or welding, steel columns feature light dead weight, high strength, and fast construction speed. As the vertical force-bearing skeleton of steel buildings, they are widely used in industrial plants, warehousing logistics, public venues, super high-rises, and bridge engineering.
Technical Specifications
| Parameter | Specification |
|---|---|
| Common Section Forms | H-beam, welded box, circular tube, cruciform, latticed |
| Common Materials | Q235B, Q355B, Q390B, Q420B |
| Section Height Range | mm ~ 1500mm (customizable for larger sections) |
| Plate Thickness Range | mm ~ 50mm |
| Single Segment Length | m ~ 15m (segmented due to transport limits) |
| Connection Method | High-strength bolt connection, full penetration welding, bolt-weld mixed connection |
| Column Base Form | Hinged (flat plate bearing), Rigid (exposed/embedded/encased) |
| Anti-corrosion Treatment | Sandblasting Sa2.5 + Epoxy/Alkyd paint, or Hot-dip galvanizing |
| Fire Protection | Fireproof coating, fireproof board, concrete encasement |
| Execution Standard | GB 50017 "Standard for Design of Steel Structures", GB 50205 "Standard for Acceptance of Construction Quality of Steel Structures" |
Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.
Advantages vs Engineering Considerations
| Advantages | Engineering Considerations |
|---|---|
| Lightweight, high bearing capacity: Under the same load, the weight is only 1/3~1/2 of concrete columns, significantly reducing foundation cost and increasing usable headroom. | Requires anti-corrosion treatment: Steel is prone to rust; must undergo derusting + painting or hot-dip galvanizing based on the environment. Coastal/chemical areas require thicker coatings. |
| Prefabricated in factory, efficient construction: Standardized production and on-site bolt assembly shorten the schedule by about 1/3 compared to concrete structures. | Requires fire protection: Steel's mechanical properties degrade rapidly at high temperatures; fireproof coatings or cladding are mandatory according to fire resistance ratings. |
| Excellent seismic performance: Good plasticity and toughness of steel can absorb and dissipate energy during earthquakes, providing high structural ductility. | High installation precision required: Column base elevation and verticality must be strictly controlled, which can be met through mature construction techniques. |
| Flexible section selection: H-shape, box, circular tube, and latticed columns can be customized to adapt to various loads and architectural designs. | Slenderness ratio must be controlled: Columns with a high slenderness ratio require professional calculation and bracing systems, guaranteed by design institute verification. |
| Recyclable: High material recovery rate after demolition, aligning with green building and circular economy directions. | Cost affected by steel market fluctuations: Material costs can be controlled via advance price locking and comparing multiple steel mills. |
Frequently Asked Questions
What are the types of steel columns?
By section: H-beam, box, circular tube, cruciform, latticed columns; by force: axially loaded, frame, and bent columns.
Which is lighter, steel or concrete column?
Under equal bearing capacity, steel column weight is about 1/3~1/2 of concrete, significantly reducing foundation size and embedment depth.
What are the common materials for steel columns?
Q235B and Q355B for industrial plants; Q390B and Q420B for high-rises and heavy-duty structures.
What are the forms of steel column bases?
Hinged base (flat plate bearing) and rigid base (exposed, embedded, encased), determined by structural calculations.
How are steel columns connected to the foundation?
By fixing the base plate with embedded anchor bolts, followed by secondary non-shrink grouting for leveling; shear keys may be required depending on the structure.
How are on-site joints of steel columns connected?
Flange full penetration groove welding + web high-strength bolt connection, or fully bolted, or fully welded.
How to do anti-corrosion for steel columns?
Sandblasting to Sa2.5, coating with epoxy/alkyd paint (total dry film thickness designed per environment class), or overall hot-dip galvanizing.
How to do fire protection for steel columns?
Apply thin or thick intumescent/fireproof coatings according to fire resistance ratings, or clad with fireproof boards or concrete.
Where are latticed columns used?
Suitable for large load, large span, and large slenderness ratio columns, such as trestles, pipe supports, and heavy-duty plant columns.
What is the allowable deviation for column verticality?
Per GB 50205, single-tier column verticality deviation is H/1000 and ≤25mm; multi-tier columns are controlled per tier.
Space Frame Pipe Strut
Technical Specifications
| Parameter | Specification |
|---|---|
| Common Sections | Circular tube φ48×3~φ299×18 |
| Material | Q235B, Q355B, Q390B |
| Node Forms | Bolted sphere nodes, welded sphere nodes, tubular intersecting nodes, plate nodes |
| Stress Characteristics | Primarily axial force (tension or compression) |
| Slenderness Ratio | Tension members ≤220, compression members ≤180 (per codes) |
| Connection Method | Welding, bolting, intersecting cutting welding |
| Anti-corrosion | Sandblasting + paint, or hot-dip galvanizing |
| Applicable Structures | Trusses, space frames, reticulated shells |
| End Processing | Welded cone head/sealing plate, intersecting cutting |
| Execution Standard | GB 50017, JGJ 7 “Technical specification for space frame structures” |
Values are the range we fabricate routinely. Project-specific sizes, grades and coating systems are confirmed on the approved shop drawing before release to production.
Advantages vs Engineering Considerations
| Advantages | Engineering Considerations |
|---|---|
| Rational stress distribution: Two-force member sections only bear axial force, maximizing material utilization. | Complex nodes: Intersecting cutting and spherical node processing require high precision. |
| Light dead weight: Truss structures save over 30% steel compared to solid-web beams. | High installation precision required: Member length and node position deviations directly affect assembly. |
| Suitable for large spans: Can achieve large-span roofs over 50m. | High anti-corrosion/fire protection requirements: Spatial structures have complex surfaces, making coating construction difficult. |
| Factory prefabrication: Standardized factory production, on-site assembly. | Node fatigue needs attention: Node welds easily crack under repeated loads; fatigue verification is needed. |
| Aesthetically pleasing: Can form various spatial curved surfaces and architectural shapes. | Relatively high cost: Processing and installation fees are higher than ordinary steel beams. |
Frequently Asked Questions
What is a Space Frame Pipe Strut?
The basic force-bearing unit in spatial structures like trusses, space frames, and reticulated shells, mostly acting as two-force members.
What sections are commonly used for space frame pipe strut?
Circular tubes are most common for space frames; trusses can also use square tubes, double angles, or H-beams.
What are the stress characteristics of space frame pipe strut?
Primarily axial forces (tension or compression), with very small bending moments.
What are the node types for space frame pipe strut?
Bolted sphere nodes, welded sphere nodes, intersecting nodes, and plate nodes.
What are the slenderness ratio limits for space frame pipe strut?
Tension space frame pipe strut generally ≤220, compression space frame pipe strut ≤180.
How are circular tube member ends processed?
Welded with space frame cone/space frame sealing plate, or directly welded to nodes via intersecting line cutting.
What materials are used for space frame pipe strut?
Q235B, Q355B, Q390B; Q420 can be used for large spans and heavy loads.
How to do anti-corrosion for space frame pipe strut?
Sandblasting + epoxy/alkyd paint; outdoor applications can also use hot-dip galvanizing.
What are the installation precision requirements?
Length deviations and node position deviations must be strictly controlled, otherwise assembly fails.
What are the advantages of space frame pipe strut over solid-web beams?
Steel-saving, suitable for large spans, flexible styling, though processing and installation costs are higher.
Qualification Certificate
Your projects are protected by world-class standards. From CE (EN 1090) to ISO 9001, our qualifications are not just paper—they are the rigorous daily reality on our shop floor.




Have drawings or a BOQ ready?
Related Projects
Projects where this sub-system was detailed, fabricated and shipped as part of the structural package.
SynJect:Scale. Precision. Certainty.
SYNJECT delivers comprehensive steel structure solutions engineered for the global value chain. From investors seeking ROI to engineers demanding exact compliance, we transform complex blueprints into robust realities—on time and without friction.
From Blueprint to Site. Zero Friction.











Detailed Engineering
Utilizing advanced BIM platforms such as Tekla Structures, detailed 3D modeling and shop drawings are executed strictly in compliance with AISC 360 or Eurocode 3 (EN 1993). Connection designs are rigorously verified, with manufacturing drawings generated to ISO 2768-m tolerance standards. 100% clash detection with primary architectural and MEP systems is performed to ensure zero structural conflicts during field erection.
Nesting & Material Optimization
Intelligent nesting layouts are performed using advanced software like FastCAM/SigmaNEST in accordance with EN 10029 / ASTM A6 dimensional standards. Accounting for cutting kerf (2mm–5mm depending on plate thickness) and thermal contraction allowances, raw material utilization exceeds 92%. Offcuts are digitally barcode-tracked to ensure 100% mill test report (MTR) traceability.
Raw Material Incoming Inspection
All structural steel (Q355B/C/D, ASTM A572 Gr.50, S355JR/J2) must be accompanied by EN 10204 3.1 Mill Test Reports (MTR). Incoming quality control conducts 100% dimensional and visual inspections under ASTM A6 / EN 10029, verifying thickness tolerances (Class A/B) and internal lamination integrity via Ultrasonic Testing (UT) to ASTM A435. Chemical composition and mechanical properties are spot-verified by accredited 3rd-party labs.
CNC Cutting & Edge Preparation
Plate profiling and component cutting are executed via CNC oxy-fuel, high-definition plasma, and multi-kW fiber laser equipment. Cut surface quality strictly complies with EN ISO 9013 for perpendicularity and surface roughness ±2.5°, Range 3/4 tolerance. Multi-axis CNC beveling machines execute weld prep bevel angles within ±2.5° and root face dimensions within ±1.0 mm.
Weld Distortion Straightening
Welding is performed exclusively by AWS D1.1 or EN ISO 9606 certified welders using qualified Welding Procedure Specifications (WPS) supported by Procedure Qualification Records (PQR) per AWS D1.1 / ISO 15614. Submerged Arc Welding (SAW) and Flux-Cored Arc Welding (FCAW) dominate Complete Joint Penetration (CJP) and fillet welds. Heat input is strictly controlled, achieving weld quality levels conforming to ISO 5817 Quality Level B or AWS D1.1 standards.
Non-Destructive Testing (NDT)
Post-weld angular distortion, camber, and sweep are rectified using automated hydraulic flange straighteners and controlled thermal flame straightening. Heating temperatures for High-Strength Low-Alloy (HSLA) steels are strictly maintained between 600℃ - 650℃ (air-cooled, zero water quenching) to prevent microstructural degradation. Post-straightening straightness tolerances meet ±3 mm, conforming to EN 1090-2 Execution Class 2 (EXC2) and AISC COSP standards.
Trial Assembly & Shop Alignment
NDT protocols are operated by ISO 9712 / ASNT Level II certified NDT personnel. 100% of critical Complete Joint Penetration (CJP) welds undergo Ultrasonic Testing (UT per ISO 17640 / ASTM E164) or Magnetic Particle Testing (MT per ISO 17638 / ASTM E709). Radiographic Testing (RT) is applied as requested for heavy sections. Weld acceptance conforms strictly to ISO 11666 Acceptance Level 1 or AWS D1.1 criteria.
Surface Preparation & Protective Coating
Complex geometries, long-span trusses, and heavy framing undergo 1:1 physical trial assembly or high-precision 3D laser scanning virtual assembly per EN 1090-2 / AISC requirements. Bolt hole alignment is verified (≥ 95% free-pass rate for high-strength bolts), and critical dimensions (span, camber, 3D spatial alignment) are verified within tight tolerance limits (±2.0 mm) to eliminate site fitting risks.
Measure Paint Film Thickness
Structural members undergo automated shot blasting to achieve SSPC-SP10 / NACE No. 2 / ISO 8501-1 Sa 2.5 cleanliness, with a surface profile (anchor depth) of 45–75μm. High-performance protective coatings are applied using airless spray technology in compliance with ISO 12944 (C3 to CX corrosive environments), featuring Inorganic/Organic Zinc-Rich Epoxy Primers, Epoxy Micaceous Iron Oxide Intermediate coats, and Polyurethane/Fluorocarbon Topcoats. Dry Film Thickness (DFT) is verified using calibrated magnetic gauges adhering strictly to the 90/10 rule.
Final Quality Inspection & Certification
Final Quality Control (FQC) performs a comprehensive holistic audit, inspecting paint aesthetics (zero runs, pinholes, sagging), critical geometry, bolt hole pitches, and laser/stenciled component mark traceability. A complete Manufacturing Data Report (MDR)—comprising MTRs, NDT records, coating inspection logs, and Certificates of Conformance—is compiled to support CE Marking (DoP under EN 1090) and AISC final acceptance.
Export Packaging & Logistics Protection
Protective packaging is engineered for containerized (40HQ/OT/FR) and breakbulk ocean freight under heavy maritime transit conditions. Structural members are bundled on heavy-duty steel skids with high-tensile steel strapping. Machined connections and contact surfaces are wrapped with VCI anti-corrosion film, EPE foam padding, and heavy rubber cushions. All timber packing complies fully with ISPM 15 phytosanitary standards and IMO Cargo Stowage and Securing (CSS) rules.
Global Field Erection & Site Management
We deliver international site erection supervision and turnkey EPCM construction services adhering to OSHA 1926 safety protocols, AISC COSP, and EN 1090-2 erection standards. Field teams, led by multilingual HSE and QA/QC engineers, utilize high-precision total stations to maintain structural plumbness within H/1000 (≤25mm max). High-Strength Structural Bolting is executed via calibrated Wrench or Turn-of-Nut methods with 100% torque audit documentation.
Get Your 24-Hour BOQ and Cost Plan
See how much steel tonnage and ocean freight you can save before fabrication begins
Steel Weight Savings
1:1 Tekla 3D modeling optimizes beam-column ratios to eliminate redundant material costs.
Zero-Clash Code Verification
Checked against EN 1090 and local wind/seismic loads.
Engineer-to-Engineer Review
Verified by our lead engineers—Zero pushy sales calls, Just actionable data and factory price.
CE EN 1090-1•ISO 9001•ISO 14001•ISO 45001
Lead Engineers Online
🔒 100% Private and Secure, No Spam